GEOMETRICAL OPTIMIZATION OF DENTAL IMPLANTS WITH REGARD TO OSSEOINTEGRATION

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F17%3A00317019" target="_blank" >RIV/68407700:21110/17:00317019 - isvavai.cz</a>

  • Result on the web

    <a href="https://ojs.cvut.cz/ojs/index.php/APP/article/view/4638" target="_blank" >https://ojs.cvut.cz/ojs/index.php/APP/article/view/4638</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.14311/APP.2017.13.0097" target="_blank" >10.14311/APP.2017.13.0097</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    GEOMETRICAL OPTIMIZATION OF DENTAL IMPLANTS WITH REGARD TO OSSEOINTEGRATION

  • Original language description

    A newly developed reference dental implant specimen type was subjected to numerical simulations of osseointegration. The goal of these tests was to optimize the geometry of the implant so as to reduce local stress concentrations and provide a better flow of stress through the whole implant body. Conditions for osseointegration were considered when evaluating the anchoring system of the implant in regard to its placement in the human cancellous and cortical bone. Numerical simulations showed that stress concentrations occur mostly in the upper cylindrical part of the implant. By increasing the width of this cylindrical part, we were able to reduce the maximum values of von-Mises stress by 20 %.

  • Czech name

  • Czech description

Classification

  • Type

    D - Article in proceedings

  • CEP classification

  • OECD FORD branch

    30404 - Biomaterials (as related to medical implants, devices, sensors)

Result continuities

  • Project

  • Continuities

    S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2017

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    NMM 2017 - Nano & Macro Mechanics 2017

  • ISBN

    978-80-01-06346-0

  • ISSN

  • e-ISSN

    2336-5382

  • Number of pages

    5

  • Pages from-to

    97-101

  • Publisher name

    Czech Technical University in Prague

  • Place of publication

    Praha

  • Event location

    Praha

  • Event date

    Sep 21, 2017

  • Type of event by nationality

    EUR - Evropská akce

  • UT code for WoS article

    000433365100019