Evaluation of Sandstone Internal Structure with Application of Micro-CT and FOTOM System
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F18%3A00319906" target="_blank" >RIV/68407700:21110/18:00319906 - isvavai.cz</a>
Alternative codes found
RIV/68378297:_____/17:00478835 RIV/61989100:27240/17:10236834
Result on the web
<a href="https://link.springer.com/chapter/10.1007/978-3-319-68324-9_36" target="_blank" >https://link.springer.com/chapter/10.1007/978-3-319-68324-9_36</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/978-3-319-68324-9_36" target="_blank" >10.1007/978-3-319-68324-9_36</a>
Alternative languages
Result language
angličtina
Original language name
Evaluation of Sandstone Internal Structure with Application of Micro-CT and FOTOM System
Original language description
The sandstone internal structure is one of the most important factors controlling mechanical properties of this stone. There are many methods enabling study of the properties and character of the internal structure. The known methods are based on the penetration of a chosen medium of a detected volume into the pores or they are based on image analysis of rock slices, where fluorescent colouring highlights the pores. Unfortunately, these methods have a destructive character and, therefore, it is not possible to use the stone samples again. The possibility to re-use the samples makes the micro-CT a very useful tool. Interpretation of the micro-CT results in combination with the results of other methods may enable more detailed view into the internal structure. We studied widely used Czech sandstones using the micro-CT in the course of our experiment. Next, the acquired data was evaluated in commercial software VGStudio MAX 2.2 and also in our FOTOMNG system. We implemented new specialized module in this system for evaluating of such data. For a measure-ment we prepared several image preprocessing methods. This preprocessing is consisted for example from image binary thresholding for a better diversity be-tween inner porosity and sandstone itself or colour inversion. As addition we implemented function for cropping the samples, due to depreciation of the sam-ple borders caused by repeated measurement. We are able to calculate the value of porosity, for whole series a volume of porespace of sandstone samples or other statistical values. Results and limitations of interpretability are discussed in this article.
Czech name
—
Czech description
—
Classification
Type
D - Article in proceedings
CEP classification
—
OECD FORD branch
10201 - Computer sciences, information science, bioinformathics (hardware development to be 2.2, social aspect to be 5.8)
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2018
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Article name in the collection
Proceedings of the Second International Scientific Conference "Intelligent Information Technologies for Industry" (IITI'17)
ISBN
978-3-319-68323-2
ISSN
2194-5357
e-ISSN
2194-5365
Number of pages
8
Pages from-to
332-339
Publisher name
Springer
Place of publication
Basel
Event location
Varna
Event date
Sep 14, 2017
Type of event by nationality
WRD - Celosvětová akce
UT code for WoS article
—