Fire test of frp members applied for the renovation of a steel railway bridge Badania pożarowe elementów z kompozytów frp przewidzianych do wykorzystania w ramach remontu wiaduktu kolejowego o konstrukcji stalowej

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F18%3A00321302" target="_blank" >RIV/68407700:21110/18:00321302 - isvavai.cz</a>

  • Result on the web

    <a href="https://doi.org/10.7409/rabdim.018.002" target="_blank" >https://doi.org/10.7409/rabdim.018.002</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.7409/rabdim.018.002" target="_blank" >10.7409/rabdim.018.002</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Fire test of frp members applied for the renovation of a steel railway bridge Badania pożarowe elementów z kompozytów frp przewidzianych do wykorzystania w ramach remontu wiaduktu kolejowego o konstrukcji stalowej

  • Original language description

    The paper outlines the on-site fire tests of FRP (fibre-reinforced polymer) products applied to a steel railway bridge. The bridge consisting of two main steel girders with a span of 9.9 m, and with timber sleepers was mounted with four different FRP floor panels on sleepers, consoles and railing systems. The FRP products differed in shape, and reaction-to-fire class. The results of the fire tests showed that only grate elements or grids with one or both coated surfaces could be accepted. Ribbed elements with the ribs oriented perpendicular to the axis of the sleepers might contribute to the progressive spread of fire to other sleepers. That is why these elements are not permitted for floors on sleepers. The shape of elements for railing construction is not limited from the viewpoint of fire safety. Good behaviour after fire can be achieved even with the profiles of reaction-to-fire class C, so it is not necessary to use fire-resistant gratings with phenol resin. The present paper concludes that FRP equipment has proved to be a suitable, durable and technically well-grounded replacement for standard steel materials for renovation of railway bridges.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>SC</sub> - Article in a specialist periodical, which is included in the SCOPUS database

  • CEP classification

  • OECD FORD branch

    20102 - Construction engineering, Municipal and structural engineering

Result continuities

  • Project

    <a href="/en/project/TE01020168" target="_blank" >TE01020168: Centre for Effective and Sustainable Transport Infrastructure (CESTI)</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2018

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Roads and Bridges - Drogi i Mosty

  • ISSN

    1643-1618

  • e-ISSN

    2449-769X

  • Volume of the periodical

    17

  • Issue of the periodical within the volume

    1

  • Country of publishing house

    PL - POLAND

  • Number of pages

    16

  • Pages from-to

    23-38

  • UT code for WoS article

    000430458000002

  • EID of the result in the Scopus database

    2-s2.0-85045951123