Influence of the external pressure tap position on the airtightness test result

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F19%3A00357283" target="_blank" >RIV/68407700:21110/19:00357283 - isvavai.cz</a>

  • Result on the web

  • DOI - Digital Object Identifier

Alternative languages

  • Result language

    angličtina

  • Original language name

    Influence of the external pressure tap position on the airtightness test result

  • Original language description

    Due to the wind induced pressure, different results may be obtained if the inside-outside pressure difference is measured across different locations on the building envelope, i.e. if the external pressure tap of a differential pressure sensor measuring this pressure difference is placed in different positions. Therefore, the position of the external pressure tap may influence an airtightness test result as well. As the wind induced pressure is linked with the wind speed, it can be expected that the influence of the external pressure tap position on the airtightness test result would be amplified with increasing wind speed. The aim of this full-scale experiment is to quantify the variability of the airtightness test results obtained under repeatability conditions with different external pressure tap positions in function of the wind speed. The motivation is a better understanding of the real influence of the wind allowing a better estimation of the measurement uncertainty as well as possible improvement of the measurement technique.

  • Czech name

  • Czech description

Classification

  • Type

    D - Article in proceedings

  • CEP classification

  • OECD FORD branch

    20101 - Civil engineering

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2019

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    40th AIVC Conference, 8th TightVent Conference, 6th venticool Conference, From energy crisis to sustainable indoor climate – 40 years of AIVC

  • ISBN

    978-2-930471-56-3

  • ISSN

  • e-ISSN

  • Number of pages

    2

  • Pages from-to

    704-705

  • Publisher name

    AIVC INIVE EEIG

  • Place of publication

    Brussels

  • Event location

    Gent

  • Event date

    Oct 15, 2019

  • Type of event by nationality

    WRD - Celosvětová akce

  • UT code for WoS article