Methodology of IEQ assessment in energy efficient buildings

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F20%3A00345723" target="_blank" >RIV/68407700:21110/20:00345723 - isvavai.cz</a>

  • Result on the web

    <a href="https://windsorconference.com/proceedings/" target="_blank" >https://windsorconference.com/proceedings/</a>

  • DOI - Digital Object Identifier

Alternative languages

  • Result language

    angličtina

  • Original language name

    Methodology of IEQ assessment in energy efficient buildings

  • Original language description

    Contemporary design, realization and operation of buildings based on cost-effective energy savings has an impact on the quality of the indoor environment. We meet completely new questions about the indoor environment quality in buildings with high energy performance in terms of thermal comfort, air quality, acoustic, light, electromagnetic, ionic microclimate and psychological comfort. The aim of the "Smart Regions Competence Centre" project of the Czech Republic's Technology Agency is, among other, to introduce methodology for expressing the quality of the indoor environment in low-energy buildings. The reason for this project is the fact that clients are currently receiving detailed information only on the energy performance of the building - energy certificate - but they have virtually no information on real or expected quality of the indoor environment in buildings. The methodology is based on a holistic approach to integrate data from smart building control systems, short-term monitoring campaigns, and questionnaire survey among users. In the case of new buildings, the assessment is based on the simulation of the energy performance of buildings. Use of methodology is documented on the results of long-term monitoring of selected IEQ indicators (temperature, CO2, VOC, humidity, noise), energy performance and questionnaires in nZEB building.

  • Czech name

  • Czech description

Classification

  • Type

    D - Article in proceedings

  • CEP classification

  • OECD FORD branch

    20101 - Civil engineering

Result continuities

  • Project

    <a href="/en/project/FV40183" target="_blank" >FV40183: EXPANSION OF THE MANUFACTURING SYSTEM OF THE INTELLIGENT HOUSE</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2020

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    Windsor 2020 Resilient Comfort

  • ISBN

    978-1-9161876-3-4

  • ISSN

  • e-ISSN

  • Number of pages

    16

  • Pages from-to

    861-876

  • Publisher name

    Ecohouse Initiative Ltd.

  • Place of publication

    Witney

  • Event location

    Windsor

  • Event date

    Apr 16, 2020

  • Type of event by nationality

    WRD - Celosvětová akce