OPTIMIZING EFFICIENCY OF THE COMBINED SEWER OVERFLOW CHAMBER HOBAS
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F20%3A00346474" target="_blank" >RIV/68407700:21110/20:00346474 - isvavai.cz</a>
Result on the web
<a href="https://doi.org/10.14311/AP.2020.60.0493" target="_blank" >https://doi.org/10.14311/AP.2020.60.0493</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.14311/AP.2020.60.0493" target="_blank" >10.14311/AP.2020.60.0493</a>
Alternative languages
Result language
angličtina
Original language name
OPTIMIZING EFFICIENCY OF THE COMBINED SEWER OVERFLOW CHAMBER HOBAS
Original language description
The paper deals with the design of swinging self-clean screen bars and the assessment of pressure losses in the combined sewer overflow chamber (HOBAS CSO Chamber), sold by the company HOBAS. The HOBAS CSO Chamber ensures a safe transfer of rainwater during a major rain event. The main goal of the research was to determine the pressure losses of the overflow chamber under various conditions - without self-clean screen bars; with screen bars without impurities and with screen bars partially or fully clogged with various impurities. The measurements were performed on a 1 : 5 scale physical model of CSO using 4 probes for measuring level heights. From the measured values, the coefficients of local losses were calculated, which were then entered into the currently used design table of flow capacities of the CSO HOBAC Chamber. At the same time, the optimal shape of individual rods of swinging self-clean bars was investigated, so that the oscillation of the free ends of the rods supports the separation and self-cleaning function during their operation. The research was conducted on a 1 : 1 scale model, so that impurities present in the CSO during the overflow (i.e. textile, cosmetic handkerchiefs, feminine hygiene products, condoms and others) could be used directly in the measurement. At the end of the experiments, the variants of the rods of screen bars that were the most effective in the separation and self-cleaning function were selected. The self-cleaning effect, which occurs at the end of the rain event and ensures that the CSO is free of impurities and ready for further use, was subsequently tested with the selected variant of the rods.
Czech name
—
Czech description
—
Classification
Type
J<sub>SC</sub> - Article in a specialist periodical, which is included in the SCOPUS database
CEP classification
—
OECD FORD branch
20102 - Construction engineering, Municipal and structural engineering
Result continuities
Project
—
Continuities
R - Projekt Ramcoveho programu EK
Others
Publication year
2020
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Acta Polytechnica
ISSN
1210-2709
e-ISSN
1805-2363
Volume of the periodical
60
Issue of the periodical within the volume
6
Country of publishing house
CZ - CZECH REPUBLIC
Number of pages
9
Pages from-to
493-501
UT code for WoS article
000607183300006
EID of the result in the Scopus database
2-s2.0-85099652599