Comparison of Behaviour of Laminated Banister Panels with Embedded Connections
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F22%3A00359787" target="_blank" >RIV/68407700:21110/22:00359787 - isvavai.cz</a>
Result on the web
<a href="https://doi.org/10.47982/cgc.8.438" target="_blank" >https://doi.org/10.47982/cgc.8.438</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.47982/cgc.8.438" target="_blank" >10.47982/cgc.8.438</a>
Alternative languages
Result language
angličtina
Original language name
Comparison of Behaviour of Laminated Banister Panels with Embedded Connections
Original language description
Glass became a very popular building material in recent decades. Modern architecture often works with glass facades, roofs, banisters or columns. However, using glass elements in structures may be problematic due to glass elements connections. The connection must bear all stresses arising during the lifetime period and meet high aesthetical standards at the same time. Various bolted and adhesive connections were developed in order to achieve as transparent look as possible. The embedded laminated connection combines mechanical and adhesive fixing systems. The ongoing research at the Faculty of Civil Engineering of the CTU in Prague is focused on the characteristics of this type of connection. Within this research, two sets of real-scale laminated banister panels with the embedded connection were tested. The first set included the samples consisting of two 8 mm glass plies bonded with two layers of an EVA foil. The second set of samples consisted of one 10 mm glass ply and one 6 mm glass ply also bonded with two layers of an EVA foil. There was one pair of embedded steel countersunk bolts with HDPE liners in each of the lower corners. A short-term vertical load was applied on the samples. During the experiment, stresses and deflections in several points were measured. The experiments showed the collapse mode and a short-term resistance of a laminated glass panel with two sets of embedded point connections under a vertical load. It also allowed comparing the behaviour and resistance of two panels of identical total thickness differing in glass ply compositions.
Czech name
—
Czech description
—
Classification
Type
D - Article in proceedings
CEP classification
—
OECD FORD branch
20101 - Civil engineering
Result continuities
Project
<a href="/en/project/TH03010175" target="_blank" >TH03010175: Hidden Connection of Laminated Glass Panes</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2022
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Article name in the collection
Challenging Glass 8 - Conference on Architectural and Structural Applications of Glass
ISBN
—
ISSN
2589-8019
e-ISSN
2589-8019
Number of pages
7
Pages from-to
—
Publisher name
Delft University of Technology (TU Delft)
Place of publication
Delft
Event location
Ghent University
Event date
Jun 23, 2022
Type of event by nationality
WRD - Celosvětová akce
UT code for WoS article
—