All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Energy Sustainability of a Cluster of Buildings with the Application of Smart Grids and the Decentralization of Renewable Energy Sources

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F22%3A00365663" target="_blank" >RIV/68407700:21110/22:00365663 - isvavai.cz</a>

  • Result on the web

    <a href="https://doi.org/10.3390/en15051649" target="_blank" >https://doi.org/10.3390/en15051649</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.3390/en15051649" target="_blank" >10.3390/en15051649</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Energy Sustainability of a Cluster of Buildings with the Application of Smart Grids and the Decentralization of Renewable Energy Sources

  • Original language description

    The optimal design of a building and city, including the balance of their energy performance, must include requirements from a wide range of areas, especially electrical engineering, informatics, technical equipment of buildings, construction and architecture, psychology and many other fields. It is the optimal design, simulation and modelling that are most reflected in the energy requirements of buildings while meeting the requirements of energy sustainability. The impact of buildings and cities on the environment is crucial and unmistakable. It should be emphasized that an inappropriately (architecturally or technologically) designed building with state-of-the-art control technology will still have worse properties than an optimally designed building without a control system. This inspired us to design a building energy model (BEM) with the implementation of a Smart Grid in a decentralized sustainable energy system, which is a microgrid from renewable energy sources (RES). This inspired us to conduct an analysis of simulation models (simultaneous simulations) to show the possibility of their application in the process of fully satisfying energy needs in a given urban region. The main goal is to design an original methodology for the design of smart “Nearly Zero Energy Buildings” (NZEB) and subsequent energy sustainability solutions. This led us to use Hybrid Optimization of Multiple Energy Resources (HOMER), PV*SOL (2D solar software design tool for the photovoltaic system performance), Monte Carlo and DesignBuilder. The EMB was designed based on the Six Sigma design quality management methodology. In the process of integrating Smart Grids with energy efficiency solutions for buildings, an original optimization basis was designed for smart buildings and smart urban areas. The proposed EMB was verified in an experiment.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    20201 - Electrical and electronic engineering

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2022

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    MDPI Energies

  • ISSN

    1996-1073

  • e-ISSN

    1996-1073

  • Volume of the periodical

    15

  • Issue of the periodical within the volume

    5

  • Country of publishing house

    CH - SWITZERLAND

  • Number of pages

    40

  • Pages from-to

    "1 OF 40"-"40"

  • UT code for WoS article

    000768918800001

  • EID of the result in the Scopus database

    2-s2.0-85125200510