All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Experimental response of a substandard RC frame building retrofitted with GFRP sheets and slab-weakening subjected to earthquake motions

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F23%3A00361231" target="_blank" >RIV/68407700:21110/23:00361231 - isvavai.cz</a>

  • Result on the web

    <a href="https://doi.org/10.1007/s10518-022-01560-3" target="_blank" >https://doi.org/10.1007/s10518-022-01560-3</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1007/s10518-022-01560-3" target="_blank" >10.1007/s10518-022-01560-3</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Experimental response of a substandard RC frame building retrofitted with GFRP sheets and slab-weakening subjected to earthquake motions

  • Original language description

    This paper presents an experimental study on the seismic response of a 2/5 scale, 3-storey, 2-bays non-ductile reinforced concrete frame building retrofitted with glass fibre reinforced polymer sheets and weakening of the floor slab around the strengthened beam hinge region, following a partial retrofit strategy involving an upgrade of the exterior beam column (b-c) joints only. The research comprised two uni-directional shake-table experiments, including a different earthquake record each, with similar PGA, but different duration and frequency content. During the short-duration test, the specimen experienced limited inter-storey drift ratios (less than 0.6%) and presented no visible damage. During the long-duration test, instead, the specimen undertook large inter-storey drifts ratios, particularly in the first storey (3.7%), and showed large cracking in the exterior beams and crushing of the concrete at both ends of the central columns. An analysis of the spectrograms of the input and top-storey displacement motions shows that the large-amplitude response of the specimen during the long-duration test was apparently due to resonance. It was concluded that the proposed retrofit strategy was able to attain, under an adverse scenario with large inter-storey drift demands, the fundamental objectives of: (a) inverting the hierarchy of strengths and sequence of events in the critically vulnerable exterior b-c joints, relocating the damage from the panel zone into the beams at the weakened part of the slab; and (b) improving the global inelastic mechanism of the structure by shifting it from brittle/unstable to ductile/stable.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    20101 - Civil engineering

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2023

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Bulletin of Earthquake Engineering

  • ISSN

    1570-761X

  • e-ISSN

    1573-1456

  • Volume of the periodical

    21

  • Issue of the periodical within the volume

    2

  • Country of publishing house

    NL - THE KINGDOM OF THE NETHERLANDS

  • Number of pages

    33

  • Pages from-to

    893-925

  • UT code for WoS article

    000884946700001

  • EID of the result in the Scopus database

    2-s2.0-85142196988