All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Design Optimization of the Façade - Integrated Solar Thermal Collector

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F16%3A00243305" target="_blank" >RIV/68407700:21220/16:00243305 - isvavai.cz</a>

  • Alternative codes found

    RIV/68407700:21720/16:00243305

  • Result on the web

    <a href="http://stc.fs.cvut.cz/pdf16/6518.pdf?_=1460317230" target="_blank" >http://stc.fs.cvut.cz/pdf16/6518.pdf?_=1460317230</a>

  • DOI - Digital Object Identifier

Alternative languages

  • Result language

    angličtina

  • Original language name

    Design Optimization of the Façade - Integrated Solar Thermal Collector

  • Original language description

    This paper is concerned with the façade - integrated solar thermal solar collector. Façade - integrated solar thermal collectors outperform building - added solar thermal collectors due to smaller heat losses at the back of the collector. The paper analyzes the behavior of different facade collector designs by means of detailed mathematical model of solar thermal collector, focusing on both the performance and architectural aspects. Different configurations of the façade collectors based on single solar glazing, vacuum glazing and double glazing have been investigated. The results of simulation indicate, that in case of using vacuum glazing with special low-emissivity coating (emissivity 0.30, solar transmittance 0.85) and air gap 10 mm (FC3) is possible to achieve higher heat gains compared to standard façade collector solution (FC1). Moreover, façade collector alternative FC3 is two times thinner than FC1 alternative (16 mm against 34 mm).

  • Czech name

  • Czech description

Classification

  • Type

    D - Article in proceedings

  • CEP classification

    JE - Non-nuclear power engineering, energy consumption and utilization

  • OECD FORD branch

Result continuities

  • Project

    <a href="/en/project/ED2.1.00%2F03.0091" target="_blank" >ED2.1.00/03.0091: University center for energy Efficient buildings (UCEEB)</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2016

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    Studentská tvůrčí činnost 2016 - sborník konference

  • ISBN

    978-80-01-05929-6

  • ISSN

  • e-ISSN

  • Number of pages

    4

  • Pages from-to

  • Publisher name

    České vysoké učení technické v Praze, Fakulta strojní

  • Place of publication

    Praha

  • Event location

    Praha

  • Event date

    Apr 19, 2016

  • Type of event by nationality

    CST - Celostátní akce

  • UT code for WoS article