Custom ultrasonic instrumentation for flow measurement and real-time binary gas analysis in the CERN ATLAS experiment
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F17%3A00316509" target="_blank" >RIV/68407700:21220/17:00316509 - isvavai.cz</a>
Result on the web
<a href="http://iopscience.iop.org/article/10.1088/1748-0221/12/01/C01091/pdf" target="_blank" >http://iopscience.iop.org/article/10.1088/1748-0221/12/01/C01091/pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1748-0221/12/01/C01091" target="_blank" >10.1088/1748-0221/12/01/C01091</a>
Alternative languages
Result language
angličtina
Original language name
Custom ultrasonic instrumentation for flow measurement and real-time binary gas analysis in the CERN ATLAS experiment
Original language description
The development of custom ultrasonic instrumentation was motivated by the need for continuous real-time monitoring of possible leaks and mass flow measurement in the evaporative cooling systems of the ATLAS silicon trackers. The instruments use pairs of ultrasonic transducers transmitting sound bursts and measuring transit times in opposite directions. The gas flow rate is calculated from the difference in transit times, while the sound velocity is deduced from their average. The gas composition is then evaluated by comparison with a molar composition vs. sound velocity database, based on the direct dependence between sound velocity and component molar concentration in a gas mixture at a known temperature and pressure. The instrumentation has been developed in several geometries, with five instruments now integrated and in continuous operation within the ATLAS Detector Control System (DCS) and its finite state machine. One instrument monitors C3F8 coolant leaks into the Pixel detector N2 envelope with a molar resolution better than 2⋅ 10-5, and has indicated a level of 0.14 % when all the cooling loops of the recently re-installed Pixel detector are operational. Another instrument monitors air ingress into the C3F8 condenser of the new C3F8 thermosiphon coolant recirculator, with sub-percent precision. The recent effect of the introduction of a small quantity of N2 volume into the 9.5 m3 total volume of the thermosiphon system was clearly seen with this instrument. Custom microcontroller-based readout has been developed for the instruments, allowing readout into the ATLAS DCS via Modbus TCP/IP on Ethernet. The instrumentation has many potential applications where continuous binary gas composition is required, including in hydrocarbon and anaesthetic gas mixtures.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
20303 - Thermodynamics
Result continuities
Project
—
Continuities
S - Specificky vyzkum na vysokych skolach
Others
Publication year
2017
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of Instrumentation
ISSN
1748-0221
e-ISSN
1748-0221
Volume of the periodical
12
Issue of the periodical within the volume
January
Country of publishing house
GB - UNITED KINGDOM
Number of pages
8
Pages from-to
—
UT code for WoS article
000395768300091
EID of the result in the Scopus database
2-s2.0-85012065184