NUMERICAL INVESTIGATION AND VALIDATION OF THE 1 090 MW STEAM TURBINE EXHAUST HOOD FLOW FIELD
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F17%3A00320865" target="_blank" >RIV/68407700:21220/17:00320865 - isvavai.cz</a>
Alternative codes found
RIV/49193864:_____/17:N0000003
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
NUMERICAL INVESTIGATION AND VALIDATION OF THE 1 090 MW STEAM TURBINE EXHAUST HOOD FLOW FIELD
Original language description
The last-stage blade (LSB) rows and exhaust hood in low-pressure (LP) steam turbine sections are key elements of the entire LP turbine part. The cold end section affects significantly the whole LP turbine efficiency and overall turbine performance due to huge steam expansion. This expansion is strongly coupled with the diffuser and exhaust hood, which transforms kinetic energy at the stage exit into potential energy. Mentioned mechanism leads to expansion line prolongation between the stage inlet and diffuser outlet and higher turbine power output.
Czech name
—
Czech description
—
Classification
Type
D - Article in proceedings
CEP classification
—
OECD FORD branch
20301 - Mechanical engineering
Result continuities
Project
—
Continuities
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Others
Publication year
2017
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Article name in the collection
PROCEEDINGS OF THE ASME TURBO EXPO: TURBINE TECHNICAL CONFERENCE AND EXPOSITION
ISBN
978-0-7918-5095-4
ISSN
—
e-ISSN
—
Number of pages
10
Pages from-to
—
Publisher name
American Society of Mechanical Engineers - ASME
Place of publication
New York
Event location
Charlotte, North Carolina
Event date
Jun 26, 2017
Type of event by nationality
WRD - Celosvětová akce
UT code for WoS article
000412862600047