All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Birefringence test for basic load case

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F18%3A00324304" target="_blank" >RIV/68407700:21220/18:00324304 - isvavai.cz</a>

  • Result on the web

    <a href="https://www.spiedigitallibrary.org/conference-proceedings-of-spie/10743/107430R/Birefringence-test-for-basic-load-case/10.1117/12.2320543.short" target="_blank" >https://www.spiedigitallibrary.org/conference-proceedings-of-spie/10743/107430R/Birefringence-test-for-basic-load-case/10.1117/12.2320543.short</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1117/12.2320543" target="_blank" >10.1117/12.2320543</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Birefringence test for basic load case

  • Original language description

    Highly sensitive polarimeters need to be used to reveal the limit values of linear or circular retardance introduced into the optical system. The correct assessment of polarimeter’s performance needs to be done with an appropriate test sample. We propose a birefringence test sample based on a basic load case of a circular plate loaded with torsion stress. Such a test sample has many advantages for a birefringence measurement testing. There is always present a zero level of stress in the middle of the circular sample. The stress level linearly increases towards the perimeter and its slope can be set arbitrarily. There is no change of either the sample volume or its shape under torsion stress. In the paper we evaluate the birefringence of a sample under torsion stress with Jones matrix calculus. We used a torsion stressed sample to verify reliability of our proposed setup for birefringence measurement based on polarizing Mach-Zehnder interferometer.

  • Czech name

  • Czech description

Classification

  • Type

    D - Article in proceedings

  • CEP classification

  • OECD FORD branch

    20302 - Applied mechanics

Result continuities

  • Project

    <a href="/en/project/TH02010264" target="_blank" >TH02010264: Implementation of multi-physics numerical analysis into the development process opto-mechanical systems</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2018

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    Proceedings Volume 10743, Optical Modeling and Performance Predictions X

  • ISBN

    9781510620582

  • ISSN

  • e-ISSN

    1996-756X

  • Number of pages

    11

  • Pages from-to

  • Publisher name

    SPIE

  • Place of publication

    Bellingham

  • Event location

    San Diego

  • Event date

    Aug 19, 2018

  • Type of event by nationality

    WRD - Celosvětová akce

  • UT code for WoS article

    000451772200019