Use of durometer to determine trapezius muscle relaxation
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F19%3A00337533" target="_blank" >RIV/68407700:21220/19:00337533 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Use of durometer to determine trapezius muscle relaxation
Original language description
Measurement of the muscle tension are normally done with specialized apparatus, a.k.a. myotonometers. These devices need specialized personnel, sophisticated electric drive, feedback control and mostly static construction. Hence the high purchase and operating costs of these devices. For these reasons, the requirement for our device arose. The basic requirements are the manual size of the apparatus and the possibility of measuring various muscles all over the body. The apparatus works on the principle of indentor injection into the tissue. The measured quantity is the resistance that the tissue puts. The maximum indentation depth is adjustable and constant during all partial measurements. Another use of apparatus is to objectify the Palpation Test. The evaluation of this test is highly subjective and depends on the experience of the implementing specialist. With help of this apparatus it is possible to visualize result while facilitating the transfer of experience among clinical experts. The apparatus is designed to by attached to the respective muscles and the indentor is manually pushed into the muscle. A compression spring is used to reverse movement. The threaded rod is used as a beam between the measuring sensor and the handle. This makes it possible to use nuts as an adjustable depth of indentation. The measuring sensor is one-Axis pressure gauge from Kisler.
Czech name
—
Czech description
—
Classification
Type
D - Article in proceedings
CEP classification
—
OECD FORD branch
20301 - Mechanical engineering
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2019
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Article name in the collection
EAN 2019 57th conference on experimental stress analysis CONFERENCE PROCEEDINGS
ISBN
9788021457669
ISSN
—
e-ISSN
—
Number of pages
4
Pages from-to
517-520
Publisher name
Česká společnost pro mechaniku
Place of publication
Praha
Event location
Luhačovice
Event date
Jun 3, 2019
Type of event by nationality
WRD - Celosvětová akce
UT code for WoS article
000568113800082