All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Collector-based measurement of gas desorption and secondary electron emission induced by 0–1.4 keV electrons from LHC-grade copper at 15 K

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F22%3A00360277" target="_blank" >RIV/68407700:21220/22:00360277 - isvavai.cz</a>

  • Result on the web

    <a href="https://doi.org/10.1016/j.nimb.2022.09.013" target="_blank" >https://doi.org/10.1016/j.nimb.2022.09.013</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.nimb.2022.09.013" target="_blank" >10.1016/j.nimb.2022.09.013</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Collector-based measurement of gas desorption and secondary electron emission induced by 0–1.4 keV electrons from LHC-grade copper at 15 K

  • Original language description

    CERN’s Large Hadron Collider cryomagnets embed a 1.9 K UHV chamber lined with a 5 - 20 K beam-screen (BS) that intercepts the synchrotron radiation and electron cloud (EC). The low–energy EC irradiates the BS and desorbs gas, creating a dynamic vacuum effect. A novel setup controllably reproduces this by irradiating an unbaked as-received BS copper sample at 15 K with 0 - 1.4 keV electrons, representing a slice of the EC spectrum. This collector-based setup is qualified using a HOPG reference for secondary electron yield (SEY) and 15N2 as a tracer in low-energy electron stimulated desorption (ESD) measurements. Measurement at 15 K revealed sub-10 eV ESD thresholds and a maximum around 300 eV of 0.18 H2/e- and 0.13 CO/e-. Irradiation with 300 eV and 1 keV electrons at ~ 8.10-4 C.mm-2 conditioned ESD and SEY alike. Similar dose at 17 eV only caused minor SEY reduction and no ESD decline. The as-received H2 and CO2 yields at 300 eV decreased 5 - 150x between 15 and 265 K, respectively.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    10302 - Condensed matter physics (including formerly solid state physics, supercond.)

Result continuities

  • Project

  • Continuities

    S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2022

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Nuclear Instruments and Methods in Physics Research, Section B, Beam Interactions with Materials and Atoms

  • ISSN

    0168-583X

  • e-ISSN

    1872-9584

  • Volume of the periodical

    531

  • Issue of the periodical within the volume

    november

  • Country of publishing house

    NL - THE KINGDOM OF THE NETHERLANDS

  • Number of pages

    10

  • Pages from-to

    34-43

  • UT code for WoS article

    000868577600004

  • EID of the result in the Scopus database

    2-s2.0-85139018510