Effect of porous density of twisted tape inserts on heat transfer performance inside a closed conduit
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F23%3A00368943" target="_blank" >RIV/68407700:21220/23:00368943 - isvavai.cz</a>
Result on the web
<a href="https://doi.org/10.1016/j.heliyon.2023.e21206" target="_blank" >https://doi.org/10.1016/j.heliyon.2023.e21206</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.heliyon.2023.e21206" target="_blank" >10.1016/j.heliyon.2023.e21206</a>
Alternative languages
Result language
angličtina
Original language name
Effect of porous density of twisted tape inserts on heat transfer performance inside a closed conduit
Original language description
This study examines the impact of varying the porosity density of twisted tape inserts (TTI) on the temperature distribution, fluid velocities, heat transfer coefficients (HTC), Nusselt numbers (Nu), turbulent kinetic energy (TKE), and performance from 5000 to 12500 Reynolds numbers (Re). The entire process involved the design of TTIs and double pipe heat exchangers using SolidWorks. Subsequently, a three-dimensional fluid flow model was employed to solve equations related to energy mass, energy, and momentum within the ANSYS Fluent interfaces. The findings highlight the noteworthy impact of high porosity TTIs, which consistently reduce temperature spans, increase fluid velocities, and greatly HTC and Nu when compared to low porosity TTI, typical TTI, and plain tubes. Furthermore, high porosity TTI significantly increases TKE, indicating increased fluid turbulence and higher heat transfer efficiency, especially at Re = 12500. The assessment of PEC emphasizes the superiority of high porosity TTI, demonstrating their significant performance increase potential of over 6.44 % over low porosity TTI and a staggering 62.5 % above typical TTI. In conclusion, high porosity TTI emerges as a potential solution for improving heat transfer efficiency and overall system performance in a variety of industrial applications, promising enhanced energy efficiency and superior performance.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
20303 - Thermodynamics
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2023
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Heliyon
ISSN
2405-8440
e-ISSN
—
Volume of the periodical
2023 (9)
Issue of the periodical within the volume
11
Country of publishing house
GB - UNITED KINGDOM
Number of pages
34
Pages from-to
—
UT code for WoS article
001102317400001
EID of the result in the Scopus database
2-s2.0-85174800299