All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Verification of Mechanical and Fatigue Strength of SAPHIRE Device in Treatment of Multi-fragmentary Fracture at Neck and Head Portions of the Proximal Humerus

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F25%3A00387705" target="_blank" >RIV/68407700:21220/25:00387705 - isvavai.cz</a>

  • Result on the web

  • DOI - Digital Object Identifier

Alternative languages

  • Result language

    angličtina

  • Original language name

    Verification of Mechanical and Fatigue Strength of SAPHIRE Device in Treatment of Multi-fragmentary Fracture at Neck and Head Portions of the Proximal Humerus

  • Original language description

    Using of SAPHIRE device with proximal humerus plate and six screws at the proximal humerus zone (as organized in construct B2) would cause distributed extent of stress and thus, significant reduction of maximum stress at proximal humerus plate and screws. This enhanced achievement would be revealed for all load types (compressive, compressive-shear, and torsion loads), which verifies the superior advantage of SAPHIRE device for treatment of complex multi-fragmentary fracture at the neck zone of the humeral head. Likewise, using of SAPHIRE device with the nail-screw system, at the proximal humerus zone, as organized in construct B6, would provide good level of stiffness compared to proximal humerus plating system for treatment of complex fracture pattern at the humeral head.

  • Czech name

  • Czech description

Classification

  • Type

    O - Miscellaneous

  • CEP classification

  • OECD FORD branch

    20602 - Medical laboratory technology (including laboratory samples analysis; diagnostic technologies) (Biomaterials to be 2.9 [physical characteristics of living material as related to medical implants, devices, sensors])

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2025

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů