All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Reducing false positive responses in lung nodule detector system by asymmetric AdaBoost

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F08%3A03144356" target="_blank" >RIV/68407700:21230/08:03144356 - isvavai.cz</a>

  • Result on the web

  • DOI - Digital Object Identifier

Alternative languages

  • Result language

    angličtina

  • Original language name

    Reducing false positive responses in lung nodule detector system by asymmetric AdaBoost

  • Original language description

    We are developing a complex computer aided diagnosis (CAD) system to detect small pulmonary nodules from helical CT scans. Here we present a classifier to reduce the number of false positive responses of the primary detector. Our approach is based on anasymmetric Adaboost which enables us to give different weights to missed nodules (false negatives, FNs) and incorrectly detected structures (false positives, FPs). This is useful because there are noticeably more negative examples in the nodule candidateset than real nodules-true positives (TPs). The whole system is meant as a second opinion for a human radiologist to speed up reading the examination. That is why we should detect as many true nodules as possible, while a certain number of FPs is acceptable. The system was tested on 147 cases (36559 slices) containing 357 nodules marked by an expert radiologist. The new classifier significantly reduced the number of false positives, while only a few nodules were incorrectly omitted.

  • Czech name

    Reducing false positive responses in lung nodule detector system by asymmetric AdaBoost

  • Czech description

    We are developing a complex computer aided diagnosis (CAD) system to detect small pulmonary nodules from helical CT scans. Here we present a classifier to reduce the number of false positive responses of the primary detector. Our approach is based on anasymmetric Adaboost which enables us to give different weights to missed nodules (false negatives, FNs) and incorrectly detected structures (false positives, FPs). This is useful because there are noticeably more negative examples in the nodule candidateset than real nodules-true positives (TPs). The whole system is meant as a second opinion for a human radiologist to speed up reading the examination. That is why we should detect as many true nodules as possible, while a certain number of FPs is acceptable. The system was tested on 147 cases (36559 slices) containing 357 nodules marked by an expert radiologist. The new classifier significantly reduced the number of false positives, while only a few nodules were incorrectly omitted.

Classification

  • Type

    D - Article in proceedings

  • CEP classification

    JD - Use of computers, robotics and its application

  • OECD FORD branch

Result continuities

  • Project

    Result was created during the realization of more than one project. More information in the Projects tab.

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2008

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    Proceedings of 2008 IEEE International Symposium on Biomedical Imaging: From Nano to Macro

  • ISBN

    978-1-4244-2002-5

  • ISSN

    1945-7928

  • e-ISSN

  • Number of pages

    4

  • Pages from-to

  • Publisher name

    IEEE

  • Place of publication

    New York

  • Event location

    Paris

  • Event date

    May 14, 2008

  • Type of event by nationality

    WRD - Celosvětová akce

  • UT code for WoS article

    000258259800165