Inteligent Power Supply Unit for the Communication System of the Czech Antarctic Station

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F11%3A00188302" target="_blank" >RIV/68407700:21230/11:00188302 - isvavai.cz</a>

  • Result on the web

  • DOI - Digital Object Identifier

Alternative languages

  • Result language

    čeština

  • Original language name

    Inteligentní napájecí jednotka pro komunikační zařízení české polární základny

  • Original language description

    The intelligent power supply unit ensures reliable feed of four 12VDC and one 5VDC power outputs. The unit is equipped by two external power inputs. One with rating 9-70VDC/5A and second with rating 9-20VDC/5A. The power unit is controlled using synchronous serial communication protocol based on the command-acknowledge-reply scheme with RS-232 interface. Control of power outputs is driven by setting of back-off, period and power-on time of every single 12VDC and 5VDC output. The unit is also equipped bysensors for monitoring currents, voltage, battery charging current, battery capacity and temperature. Unit is actively controlling the battery charging process according to temperature to provide the higher battery lifetime and capacity.

  • Czech name

    Inteligentní napájecí jednotka pro komunikační zařízení české polární základny

  • Czech description

    The intelligent power supply unit ensures reliable feed of four 12VDC and one 5VDC power outputs. The unit is equipped by two external power inputs. One with rating 9-70VDC/5A and second with rating 9-20VDC/5A. The power unit is controlled using synchronous serial communication protocol based on the command-acknowledge-reply scheme with RS-232 interface. Control of power outputs is driven by setting of back-off, period and power-on time of every single 12VDC and 5VDC output. The unit is also equipped bysensors for monitoring currents, voltage, battery charging current, battery capacity and temperature. Unit is actively controlling the battery charging process according to temperature to provide the higher battery lifetime and capacity.

Classification

  • Type

    G<sub>funk</sub> - Functional sample

  • CEP classification

    JA - Electronics and optoelectronics

  • OECD FORD branch

Result continuities

  • Project

  • Continuities

    S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2011

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Internal product ID

    Bender III PWR

  • Numerical identification

  • Technical parameters

    Výstupy napájení 4x12 VDC 1x5 VDC. Vstupy 9 - 70 VDC/5 A a 9 - 20 VDC/ 5 A. Řízení RS-232, úprava nabíjecího procesu dle aktuální teploty. Vlastníkem výsledku je ČVUT v Praze, IČ 68407700.

  • Economical parameters

    Poskytnuto bezplatně pro Geografický ústav, Přírodovědecká fakulta Masarykovy univerzity IČ 00216224 - Smlouva o spolupráci a využití výsledků výzkumu a vývoje při řešení komunikace s českou polární základnou ze dne 1.12. 2010.

  • Application category by cost

  • Owner IČO

    68407700

  • Owner name

    ČVUT FEL

  • Owner country

    CZ - CZECH REPUBLIC

  • Usage type

    P - Využití výsledku jiným subjektem je v některých případech možné bez nabytí licence