Advanced Applications of FACTS in Industrial Distribution Systems in Middle Europe
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F12%3A00200099" target="_blank" >RIV/68407700:21230/12:00200099 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Advanced Applications of FACTS in Industrial Distribution Systems in Middle Europe
Original language description
The paper deals with the possibilities of FACTS devices installation and operation in the Middle European distribution systems. A voltage fluctuation that results in flicker is caused by Electrical Arc Furnace (EAF) power fluctuation. The UPQC can be aneffective means to suppress voltage fluctuation connected with the function of the EAF. Hitherto, the flicker has been compensated for mainly by using Static Var Compensators (SVC), whose capability to eliminate voltage subharmonics is limited by the frequency up to 10 Hz at maximum. A model of a power system with an electric arc furnace was developed for a typical metallurgical plant. The paper would like to emphasize that FACTS devices should have their position not only in large transmission system but for specific tasks also in local distribution systems. This is all connected with technical-economical decision how to approach to solving all partial electrical systems operational issues.
Czech name
—
Czech description
—
Classification
Type
O - Miscellaneous
CEP classification
JE - Non-nuclear power engineering, energy consumption and utilization
OECD FORD branch
—
Result continuities
Project
—
Continuities
S - Specificky vyzkum na vysokych skolach
Others
Publication year
2012
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů