Detection of Artifacts in Oscillometric Pulsations Signals
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F14%3A00219419" target="_blank" >RIV/68407700:21230/14:00219419 - isvavai.cz</a>
Result on the web
<a href="http://emb.citengine.com/event/bhi-2014/details" target="_blank" >http://emb.citengine.com/event/bhi-2014/details</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/BHI.2014.6864462" target="_blank" >10.1109/BHI.2014.6864462</a>
Alternative languages
Result language
angličtina
Original language name
Detection of Artifacts in Oscillometric Pulsations Signals
Original language description
A measurement of blood pressure is a basic diagnostic technique for examining of the cardiovascular system. There are a lot of methods for determination of the blood pressure, but an oscillometric measurement (investigation of oscillometric pulsations) is one of the most frequent methods used in modern electronic tonometers. The results given by oscillometric measurements are very dependent on the cleanness of the signal. The method is very sensitive for example for motion artifacts, which produce significant damage of the signal. For the proper processing of the signal it is very important to detect all artifacts precisely before signal processing. The paper deals with the methods for artifacts detection in oscillometric pulsations signals. The methods based on predicted heart rate detection, heart rate variability (standard deviation method) and comparison of oscillometric pulsations with ECG signal are described in the paper. The section Results includes a comparison of the methods
Czech name
—
Czech description
—
Classification
Type
D - Article in proceedings
CEP classification
JA - Electronics and optoelectronics
OECD FORD branch
—
Result continuities
Project
—
Continuities
S - Specificky vyzkum na vysokych skolach
Others
Publication year
2014
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Article name in the collection
International Conference on Biomedical and Health Informatics
ISBN
978-1-4799-2131-7
ISSN
—
e-ISSN
—
Number of pages
3
Pages from-to
709-711
Publisher name
IEEE Engineering in Medicine and Biology Society
Place of publication
New Jersey
Event location
Valencia
Event date
Jun 1, 2014
Type of event by nationality
WRD - Celosvětová akce
UT code for WoS article
000346504900170