Calibration of AC clamp Meters
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F16%3A00242995" target="_blank" >RIV/68407700:21230/16:00242995 - isvavai.cz</a>
Result on the web
<a href="http://dx.doi.org/10.1109/TIM.2015.2507413" target="_blank" >http://dx.doi.org/10.1109/TIM.2015.2507413</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/TIM.2015.2507413" target="_blank" >10.1109/TIM.2015.2507413</a>
Alternative languages
Result language
angličtina
Original language name
Calibration of AC clamp Meters
Original language description
This paper presents a method for calibrating ac clamp meters for power and energy measurements. A procedure for determining the ratio error and the phase displacement in a wider frequency range up to 10 kHz is also analyzed. The results of measurements of both types of error for two clamp meters are presented at the end of this paper.
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
JB - Sensors, detecting elements, measurement and regulation
OECD FORD branch
—
Result continuities
Project
—
Continuities
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Others
Publication year
2016
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
IEEE Transactions on Instrumentation and Measurement
ISSN
0018-9456
e-ISSN
—
Volume of the periodical
65
Issue of the periodical within the volume
5
Country of publishing house
US - UNITED STATES
Number of pages
7
Pages from-to
1156-1162
UT code for WoS article
000374892500023