Cost Implication and Reactive Power Generating Potential of the Synchronous Condenser

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F16%3A00305729" target="_blank" >RIV/68407700:21230/16:00305729 - isvavai.cz</a>

  • Result on the web

    <a href="http://dx.doi.org/10.1109/IGBSG.2016.7539450" target="_blank" >http://dx.doi.org/10.1109/IGBSG.2016.7539450</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1109/IGBSG.2016.7539450" target="_blank" >10.1109/IGBSG.2016.7539450</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Cost Implication and Reactive Power Generating Potential of the Synchronous Condenser

  • Original language description

    The objective of this study is to examine the cost implication and reactive power generating potential of the synchronous condenser. Universally, increase in electricity demand constitutes new issues for power generation, transmission and distribution. Synchronous condenser solutions are being initiated globally to be instrumental in the best usage of power resources and offer grid systems support for todays and future sustainable, stable and reliable electrical grid network. This research x-rays the cost implication of the synchronous condenser in today's challenging environment. A vivid description of the reactive power generating potential of the synchronous condenser is shown with Matlab/Simulink environment simulation of a medium voltage (MV) power system network. It is observed that the synchronous condenser is cost-effective as compared to other reactive power generating equipment's and sources. Furthermore, Matlab/Simulink simulation results of the MV electric-power network shows an effective scheme for reactive power generation.

  • Czech name

  • Czech description

Classification

  • Type

    D - Article in proceedings

  • CEP classification

    JE - Non-nuclear power engineering, energy consumption and utilization

  • OECD FORD branch

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2016

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    The Proceedings of the 2nd International Conference on Intelligent Green Building and Smart Grid (IGBSG)

  • ISBN

    978-1-4673-8473-5

  • ISSN

  • e-ISSN

  • Number of pages

    6

  • Pages from-to

    212-217

  • Publisher name

    IEEE Czechoslovakia Section

  • Place of publication

    Praha

  • Event location

    Praha

  • Event date

    Jun 27, 2016

  • Type of event by nationality

    WRD - Celosvětová akce

  • UT code for WoS article

    000389772400040