All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Off-Center Error Correction of AMR Yokeless Current Transducer

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F17%3A00314512" target="_blank" >RIV/68407700:21230/17:00314512 - isvavai.cz</a>

  • Result on the web

    <a href="https://www.hindawi.com/journals/js/2017/6057634/" target="_blank" >https://www.hindawi.com/journals/js/2017/6057634/</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1155/2017/6057634" target="_blank" >10.1155/2017/6057634</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Off-Center Error Correction of AMR Yokeless Current Transducer

  • Original language description

    We present a method of calibration and error correction of the AMR yokeless current transducer consisting of a circular array of eight anisotropic magnetoresistors (AMR) with one feedback compensation loop. The main sources of errors are the nonidentical parameters of AMR sensors and off-center position of the measured current. It is well known that AMR sensors from the same batch have 2% spread of the sensitivity; we found that the variation of the factor of the internal compensation coil is the same. We developed a novel calibration process using the readings of individual residual uncompensated voltages of the AMRs. The position of the current inside the measurement hole is estimated from the individual voltages considering the influence of external DC magnetic field such as the Earth’s field. During the calibration phase, the sensor outputs are measured for several positions of the current conductor inside the measuring hole. As a result of calibration the lookup table of error corrections is calculated and stored in the memory, and then these values are used for the correction during the measurement of the unknown current. This procedure reduces the off-center error from 0.4% to 0.06%.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    20201 - Electrical and electronic engineering

Result continuities

  • Project

    <a href="/en/project/GA17-19877S" target="_blank" >GA17-19877S: New methods for the measurement of electric currents</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2017

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Journal of Sensors

  • ISSN

    1687-725X

  • e-ISSN

    1687-7268

  • Volume of the periodical

    2017

  • Issue of the periodical within the volume

    October

  • Country of publishing house

    US - UNITED STATES

  • Number of pages

    7

  • Pages from-to

  • UT code for WoS article

    000414099100001

  • EID of the result in the Scopus database

    2-s2.0-85042272088