Design of reaction time measuring device
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F18%3A00324811" target="_blank" >RIV/68407700:21230/18:00324811 - isvavai.cz</a>
Alternative codes found
RIV/68407700:21260/18:00324811 RIV/68407700:21460/18:00324811
Result on the web
<a href="https://transportmeans.ktu.edu/wp-content/uploads/sites/307/2018/02/Transport-means-II-A4-2018-09-25.pdf" target="_blank" >https://transportmeans.ktu.edu/wp-content/uploads/sites/307/2018/02/Transport-means-II-A4-2018-09-25.pdf</a>
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Design of reaction time measuring device
Original language description
At present, the concept of reaction time measurement is used as one of the methods of psychological testing. Its usage spectrum, however, covers rehabilitation medicine, neurosciences and similar. Available systems used to measure reaction time deal with complex reaction time, i.e. the time between generating the stimuli and respective reaction via effector. Typical limitation is the design of these devices, which usually fits specific application, but it is not reusable for other applications. The goal of this paper is to introduce concept of device measuring reaction time of both upper and lower limbs, to visual or acoustic stimuli. Design of the device allows for application independence, i.e. it is reusable for wide range of different applications. This independence is supported by open software platform, including base set of testing tasks. In case of measurement of upper limb reaction time, the device allows measurement of individual components of the reaction time, opening new capabilities for deeper understanding of human sensory systems with respect to the speed of reaction to external stimuli.
Czech name
—
Czech description
—
Classification
Type
D - Article in proceedings
CEP classification
—
OECD FORD branch
20602 - Medical laboratory technology (including laboratory samples analysis; diagnostic technologies) (Biomaterials to be 2.9 [physical characteristics of living material as related to medical implants, devices, sensors])
Result continuities
Project
—
Continuities
S - Specificky vyzkum na vysokych skolach
Others
Publication year
2018
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Article name in the collection
TRANSPORT MEANS 2018 - PROCEEDINGS OF THE 22nd INTERNATIONAL SCIENTIFIC CONFERENCE
ISBN
—
ISSN
1822-296X
e-ISSN
2351-7034
Number of pages
5
Pages from-to
580-584
Publisher name
Kaunas University of Technology
Place of publication
Kaunas
Event location
Trakai
Event date
Oct 3, 2018
Type of event by nationality
WRD - Celosvětová akce
UT code for WoS article
—