All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Comparison of home blood pressure measurement devices in real conditions

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F18%3A00326954" target="_blank" >RIV/68407700:21230/18:00326954 - isvavai.cz</a>

  • Result on the web

    <a href="https://ieeexplore.ieee.org/document/8531139" target="_blank" >https://ieeexplore.ieee.org/document/8531139</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1109/HealthCom.2018.8531139" target="_blank" >10.1109/HealthCom.2018.8531139</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Comparison of home blood pressure measurement devices in real conditions

  • Original language description

    Cardiovascular diseases are well known as one of the leading causes of death in developed countries. The hypertension is a significant danger and should be monitored carefully. In recent decades, auscultatory and oscillometric methods become as widely used for blood pressure measurement. In clinical practice, blood pressure measuring devices are evaluated according to validating protocols. Despite these protocols, a market with the automatic devices for home self-measurement of the blood pressure is flooded by a lot of cheap devices with doubtful accuracy. The goal of the study is to compare home blood pressure measurement devices in the real conditions and using the real signals and to show the difference between the values obtained by these devices and by the clinically validated reference device. For each device, the absolute errors of the systolic and the diastolic pressures were evaluated. The obtained results show that the measurement error of these devices could be frequently higher than 5 mmHg and it is necessary to concern with the accuracy of the devices.

  • Czech name

  • Czech description

Classification

  • Type

    D - Article in proceedings

  • CEP classification

  • OECD FORD branch

    20201 - Electrical and electronic engineering

Result continuities

  • Project

  • Continuities

    S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2018

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    2018 IEEE 20th International Conference on e-Health Networking, Applications and Services (Healthcom)

  • ISBN

    978-1-5386-4294-8

  • ISSN

  • e-ISSN

  • Number of pages

    6

  • Pages from-to

  • Publisher name

    IEEE

  • Place of publication

    Piscataway

  • Event location

    Ostrava

  • Event date

    Sep 17, 2018

  • Type of event by nationality

    WRD - Celosvětová akce

  • UT code for WoS article