First Measurement of X-rays Generated by Runaway Electrons in Tokamaks Using a TimePix3 Device with 1 mm thick Silicon Sensor
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F18%3A00341375" target="_blank" >RIV/68407700:21230/18:00341375 - isvavai.cz</a>
Alternative codes found
RIV/61389021:_____/18:00522781 RIV/68407700:21340/18:00341375
Result on the web
<a href="https://doi.org/10.1109/NSSMIC.2018.8824534" target="_blank" >https://doi.org/10.1109/NSSMIC.2018.8824534</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/NSSMIC.2018.8824534" target="_blank" >10.1109/NSSMIC.2018.8824534</a>
Alternative languages
Result language
angličtina
Original language name
First Measurement of X-rays Generated by Runaway Electrons in Tokamaks Using a TimePix3 Device with 1 mm thick Silicon Sensor
Original language description
An application study of modern pixel semiconductor detectors for characterization of runaway electron events in tokamaks is presented. Characterization techniques utilizing both spectroscopic measurements and monitoring of the intensity of secondary X-rays produced by the runaway electrons were used. Energy spectra of X-rays and time evolutions of their intensity on two tokamaks (Golem and Compass) were measured under different conditions and compared with results of standard runaway diagnostics. The energy spectra measured on both tokamaks have similar exponential shapes but with a significant variation in numbers of events per shot. The time evolutions of the X-ray intensity during several discharges on the tokamak Golem were measured using both the Timepix3 device and scintillation detectors (NaI:Tl and YAP:Ce). On a microsecond time scales, the signal time evolution measured by the TimePix3 device shows patterns in a form of unexpected or periodic-like increases of the intensity. We have also observed significant differences in number of events of the detected X-rays generated by the runaway electrons flying frontward and backward with respect to a limiter of the tokamak Golem. This fact declares that the runaway electrons have relativistic velocities. The experiments on the tokamak Compass provide similar results. Measurements in the immediate vicinity of tokamak Compass were impossible to perform because of a rapid change of the tokamak magnetic field. Measurements performed in the distance of at least 0.5 m from a diagnostic port of the tokamak Compass gave millions of correctly measured events per shot and an unknown number of events affected by pileups. The correctly measured events were used for construction of energy spectra and the time evolutions of the X-ray intensity.
Czech name
—
Czech description
—
Classification
Type
D - Article in proceedings
CEP classification
—
OECD FORD branch
10305 - Fluids and plasma physics (including surface physics)
Result continuities
Project
<a href="/en/project/GA18-02482S" target="_blank" >GA18-02482S: Radiation processes generated by runaway electrons in tokamaks</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2018
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Article name in the collection
2018 IEEE Nuclear Science Symposium and Medical Imaging Conference Proceedings (NSS/MIC)
ISBN
978-1-5386-8494-8
ISSN
—
e-ISSN
2577-0829
Number of pages
9
Pages from-to
—
Publisher name
Institute of Electrical and Electronics Engineers, Inc.
Place of publication
—
Event location
Sydney
Event date
Nov 10, 2018
Type of event by nationality
WRD - Celosvětová akce
UT code for WoS article
000601256000267