Iron Loss Minimization Strategy for Predictive Torque Control of Induction Motor

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F20%3A00340527" target="_blank" >RIV/68407700:21230/20:00340527 - isvavai.cz</a>

  • Result on the web

    <a href="https://doi.org/10.3390/electronics9040566" target="_blank" >https://doi.org/10.3390/electronics9040566</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.3390/electronics9040566" target="_blank" >10.3390/electronics9040566</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Iron Loss Minimization Strategy for Predictive Torque Control of Induction Motor

  • Original language description

    Today’s modern control strategies of an induction motor (IM) drive require a power source with an adjustable output voltage frequency and amplitude. The most commonly used converter topology is a two-level voltage-source inverter (VSI). However, the utilization of a VSI introduces additional voltage and current distortion, which leads to additional power losses in the machine’s magnetic circuit. Both the transistor switching frequency and the type of the inverter control determine the total harmonic distortion (THD) of the motor’s phase currents. In this paper, the influence of the inverter DC-link voltage on the iron losses of an IM controlled by a predictive torque control (PTC) is presented. It is shown that if the IM drive operates below the rated speed, it is possible to modify the PTC algorithm to reduce the additional iron losses caused by the non-harmonic inverter output voltage. The control of the DC-link voltage is achieved by using a silicon-controlled rectifier. Experiments were conducted on a 5.5 kW IM controlled by PTC, and the results are compared against a sinusoidal voltage supply created by a synchronous generator.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    20201 - Electrical and electronic engineering

Result continuities

  • Project

  • Continuities

    S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2020

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Electronics

  • ISSN

    2079-9292

  • e-ISSN

    2079-9292

  • Volume of the periodical

    9

  • Issue of the periodical within the volume

    4

  • Country of publishing house

    CH - SWITZERLAND

  • Number of pages

    13

  • Pages from-to

  • UT code for WoS article

    000539533200025

  • EID of the result in the Scopus database

    2-s2.0-85084700806