All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Temperature dependent dielectric spectroscopy of muscle tissue phantom

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F20%3A00341961" target="_blank" >RIV/68407700:21230/20:00341961 - isvavai.cz</a>

  • Alternative codes found

    RIV/68407700:21460/20:00341961

  • Result on the web

    <a href="https://doi.org/10.1017/S1759078720000203" target="_blank" >https://doi.org/10.1017/S1759078720000203</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1017/S1759078720000203" target="_blank" >10.1017/S1759078720000203</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Temperature dependent dielectric spectroscopy of muscle tissue phantom

  • Original language description

    The temperature dependence of the dielectric parameters of tissues and tissue-mimicking phantoms is very important for non-invasive temperature measurement in medical applications using microwaves. We performed measurements of this dependence in the temperature range 25-50 °C using distilled water as a reference liquid commonly used in dielectric properties studies. The results were compared with the literature model in the frequency range 150 – 3000 MHz. Using this method, the temperature dependence of dielectric parameters of a new muscle tissue-mimicking phantom based on agar, polyethylene powder and polysaccharide material TX-151 was measured in the temperature range 25 - 50 °C. The temperature dependence of dielectric properties of this new muscle phantom was fitted to that of the two-pole Cole-Cole model and the deviation of the results between measured and modelled data was quantified.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    20201 - Electrical and electronic engineering

Result continuities

  • Project

  • Continuities

    S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2020

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    International Journal of Microwave and Wireless Technologies

  • ISSN

    1759-0787

  • e-ISSN

    1759-0795

  • Volume of the periodical

    2020

  • Issue of the periodical within the volume

    Březen

  • Country of publishing house

    GB - UNITED KINGDOM

  • Number of pages

    7

  • Pages from-to

    885-891

  • UT code for WoS article

    000578446800011

  • EID of the result in the Scopus database

    2-s2.0-85082200971