Verification of Numerical Model for Trabecular Tissue using Compression Test and Time-Lapse X-Ray Radiography based on Material Model Determined from Three-Point Bending Test of Single Trabecula
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21260%2F14%3A00208101" target="_blank" >RIV/68407700:21260/14:00208101 - isvavai.cz</a>
Alternative codes found
RIV/68378297:_____/14:00395993 RIV/68407700:21670/14:00208101
Result on the web
<a href="http://dx.doi.org/10.4028/www.scientific.net/KEM.586.265" target="_blank" >http://dx.doi.org/10.4028/www.scientific.net/KEM.586.265</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.4028/www.scientific.net/KEM.586.265" target="_blank" >10.4028/www.scientific.net/KEM.586.265</a>
Alternative languages
Result language
angličtina
Original language name
Verification of Numerical Model for Trabecular Tissue using Compression Test and Time-Lapse X-Ray Radiography based on Material Model Determined from Three-Point Bending Test of Single Trabecula
Original language description
The aim of this study is to determine constitutive constants for elasto-plastic material model with damage for single trabecula based on the indirect simulation of micromechanical testing and its verification at macro level using compression test of thecylindrical sample of the trabecular tissue. Three-point bending test of isolated trabeculae was performed in a shielding box and deflection of the sample was acquired using X-ray microradiography. Measured values (displacements of markers) were used forindirect identification of the material model for single trabecula using finite element (FE) method. The bending test was simulated and results were fitted to experimentally obtained values and the appropriate set of material constants was determined. To verify the applicability of the identified material model the compression test of the complex sample was carried out. Cylindrical sample was incrementally loaded and each loading state was captured using the micro-computed tomography. M
Czech name
—
Czech description
—
Classification
Type
D - Article in proceedings
CEP classification
JJ - Other materials
OECD FORD branch
—
Result continuities
Project
<a href="/en/project/GAP105%2F10%2F2305" target="_blank" >GAP105/10/2305: Morphometry and mechanical properties of trabecular bone assessed by methods of micromechanics and numerical modelling</a><br>
Continuities
Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach
Others
Publication year
2014
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Article name in the collection
9th International Conference on Local Mechanical Properties
ISBN
978-3-03785-876-9
ISSN
1013-9826
e-ISSN
—
Number of pages
5
Pages from-to
265-269
Publisher name
Transtech Publications
Place of publication
Zürich
Event location
Levoča
Event date
Nov 7, 2012
Type of event by nationality
WRD - Celosvětová akce
UT code for WoS article
000336633500065