Verification of Numerical Model for Trabecular Tissue using Compression Test and Time-Lapse X-Ray Radiography based on Material Model Determined from Three-Point Bending Test of Single Trabecula

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21260%2F14%3A00208101" target="_blank" >RIV/68407700:21260/14:00208101 - isvavai.cz</a>

  • Alternative codes found

    RIV/68378297:_____/14:00395993 RIV/68407700:21670/14:00208101

  • Result on the web

    <a href="http://dx.doi.org/10.4028/www.scientific.net/KEM.586.265" target="_blank" >http://dx.doi.org/10.4028/www.scientific.net/KEM.586.265</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.4028/www.scientific.net/KEM.586.265" target="_blank" >10.4028/www.scientific.net/KEM.586.265</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Verification of Numerical Model for Trabecular Tissue using Compression Test and Time-Lapse X-Ray Radiography based on Material Model Determined from Three-Point Bending Test of Single Trabecula

  • Original language description

    The aim of this study is to determine constitutive constants for elasto-plastic material model with damage for single trabecula based on the indirect simulation of micromechanical testing and its verification at macro level using compression test of thecylindrical sample of the trabecular tissue. Three-point bending test of isolated trabeculae was performed in a shielding box and deflection of the sample was acquired using X-ray microradiography. Measured values (displacements of markers) were used forindirect identification of the material model for single trabecula using finite element (FE) method. The bending test was simulated and results were fitted to experimentally obtained values and the appropriate set of material constants was determined. To verify the applicability of the identified material model the compression test of the complex sample was carried out. Cylindrical sample was incrementally loaded and each loading state was captured using the micro-computed tomography. M

  • Czech name

  • Czech description

Classification

  • Type

    D - Article in proceedings

  • CEP classification

    JJ - Other materials

  • OECD FORD branch

Result continuities

  • Project

    <a href="/en/project/GAP105%2F10%2F2305" target="_blank" >GAP105/10/2305: Morphometry and mechanical properties of trabecular bone assessed by methods of micromechanics and numerical modelling</a><br>

  • Continuities

    Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2014

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    9th International Conference on Local Mechanical Properties

  • ISBN

    978-3-03785-876-9

  • ISSN

    1013-9826

  • e-ISSN

  • Number of pages

    5

  • Pages from-to

    265-269

  • Publisher name

    Transtech Publications

  • Place of publication

    Zürich

  • Event location

    Levoča

  • Event date

    Nov 7, 2012

  • Type of event by nationality

    WRD - Celosvětová akce

  • UT code for WoS article

    000336633500065