Effective Dose Assessment for Workers in Caves in the Czech Republic: Experiments with Passive Radon Detectors
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21340%2F08%3A04150075" target="_blank" >RIV/68407700:21340/08:04150075 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Effective Dose Assessment for Workers in Caves in the Czech Republic: Experiments with Passive Radon Detectors
Original language description
The new RAMARN system for radon volume activity measurement was developed in 2003 and has been in use since then. RAMARN consists of a plastic chamber that is conical cylindrical in shape and about 0,5 l in volume; a bare Kodak LR 115 is located on the bottom of this diffusion chamber. The size was chosen to avoid the influence of deposited RnDP. Kodak has a spectrometric character - the tracks are visualized only for alphas with energies between 1 MeV and 3 MeV that touch the foil; thus the effective volume has a lens shape. The response therefore corresponds to diffused radon and half of 218Po born by radon gas decay. The experiments described below were conducted as one part of a routine methodology control, focused on classifying worker irradiationfrom natural ionizing radiation sources in show caves and in caves used for speleotherapy.
Czech name
Stanovení efektivních dávek pro pracovníky jeskyní: experimenty s pasivními detektory
Czech description
Testování přesnosti měření integrálními detektory RAMARN pro potřeby zpřesnění odhadu dávky pro pracovníky v jeskyních proběhlo ve dvou jeskyních po dobu jednoho roku. Výsledky byly implementovány do novelizace metodiky stanovení dávky.
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
BG - Nuclear, atomic and molecular physics, accelerators
OECD FORD branch
—
Result continuities
Project
<a href="/en/project/JC_12%2F2006" target="_blank" >JC_12/2006: Enhancement of personal dosimetry for workers in publicly accessible caves and in caves used for speleotherapy, with prospect to include other underground workplaces.</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2008
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Radiation Protection Dosimetry
ISSN
0144-8420
e-ISSN
—
Volume of the periodical
130
Issue of the periodical within the volume
1
Country of publishing house
GB - UNITED KINGDOM
Number of pages
4
Pages from-to
—
UT code for WoS article
000259206500012
EID of the result in the Scopus database
—