Air Kerma Rate estimation by means of in-situ gamma spectrometry: A Bayesian approach
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21340%2F10%3A00166538" target="_blank" >RIV/68407700:21340/10:00166538 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Air Kerma Rate estimation by means of in-situ gamma spectrometry: A Bayesian approach
Original language description
Bayesian inference is used to determine the Air Kerma Rate based on in-situ gamma spectrum measurement performed with an NaI(Tl) scintillation detector. The procedure accounts for uncertainties in the measurement and in the mass energy transfer coefficients needed for the calculation. The WinBUGS program (Spiegelhalter et al., 1999) was used. The results show that the relative uncertainties in the Air Kerma estimate are of about 1%, and that the choice of unfolding procedure may lead to an estimate systematic error of 3%.
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
BG - Nuclear, atomic and molecular physics, accelerators
OECD FORD branch
—
Result continuities
Project
—
Continuities
Z - Vyzkumny zamer (s odkazem do CEZ)
Others
Publication year
2010
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Applied Radiation and Isotopes
ISSN
0969-8043
e-ISSN
—
Volume of the periodical
68
Issue of the periodical within the volume
4-5
Country of publishing house
GB - UNITED KINGDOM
Number of pages
3
Pages from-to
—
UT code for WoS article
000276418600072
EID of the result in the Scopus database
—