All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Note: Optical trigger device with sub-picosecond timing jitter and stability

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21340%2F12%3A00193011" target="_blank" >RIV/68407700:21340/12:00193011 - isvavai.cz</a>

  • Result on the web

    <a href="http://dx.doi.org/10.1063/1.3665919" target="_blank" >http://dx.doi.org/10.1063/1.3665919</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1063/1.3665919" target="_blank" >10.1063/1.3665919</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Note: Optical trigger device with sub-picosecond timing jitter and stability

  • Original language description

    This device generates an electrical signal synchronously to the detected ultra-short optical pulse. The device was designed for application in satellite laser ranging and laser time transfer experiments, time correlated photon counting and similar experiments, where picosecond timing resolution and detection delay stability are required. It consists of the ultrafast optical detector, signal discriminator, output pulse forming circuit, and output driver circuits. It was constructed as a single compact device to optimize their matching and maintain stability. The detector consists of an avalanche photodiode--both silicon and germanium types may be used to cover the wavelength range of 350-1550 nm. The analogue signal of this photodiode is sensed by the ultrafast comparator with 8 GHz bandwidth.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    JA - Electronics and optoelectronics

  • OECD FORD branch

Result continuities

  • Project

  • Continuities

    Z - Vyzkumny zamer (s odkazem do CEZ)

Others

  • Publication year

    2012

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Review of Scientific Instruments

  • ISSN

    0034-6748

  • e-ISSN

  • Volume of the periodical

    83

  • Issue of the periodical within the volume

    3

  • Country of publishing house

    US - UNITED STATES

  • Number of pages

    3

  • Pages from-to

  • UT code for WoS article

    000302227700069

  • EID of the result in the Scopus database