All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Note: Solid state photon counters with sub-picosecond timing stability

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21340%2F13%3A00207551" target="_blank" >RIV/68407700:21340/13:00207551 - isvavai.cz</a>

  • Result on the web

    <a href="http://dx.doi.org/10.1063/1.4802950" target="_blank" >http://dx.doi.org/10.1063/1.4802950</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1063/1.4802950" target="_blank" >10.1063/1.4802950</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Note: Solid state photon counters with sub-picosecond timing stability

  • Original language description

    We are reporting on a design, construction, and performance of photon counting detector packages based on solid state sensors. These photon counting devices have been optimized for extremely high stability of their detection delay. The detectors have been designed for applications in fundamental metrology and optical time transfer. The single photon avalanche diode structure manufactured on silicon using the K14 technology is used as a sensor. The active area of the sensor is circular with a diameter of100 or 200 mu m. The sensor is operated in an active quenching and gating mode. The photon detection efficiency exceeds 40% in a wavelength range spanning from 500 to 800 nm. The timing resolution is better than 20 ps rms. Its detection delay is stablewithin +/-600 fs over several days of operation, in a sense of time deviation the detection delay stability of 150 fs has been achieved. The temperature change of the detection delay is as low as 280 fs/K. This timing performance is prese

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    JB - Sensors, detecting elements, measurement and regulation

  • OECD FORD branch

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2013

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Review of Scientific Instruments

  • ISSN

    0034-6748

  • e-ISSN

  • Volume of the periodical

    84

  • Issue of the periodical within the volume

    4

  • Country of publishing house

    US - UNITED STATES

  • Number of pages

    3

  • Pages from-to

  • UT code for WoS article

    000318240900068

  • EID of the result in the Scopus database