All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Influence of preparation and calibration method of PAGAT dosimeter on TSE MR readout results

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21340%2F13%3A00213992" target="_blank" >RIV/68407700:21340/13:00213992 - isvavai.cz</a>

  • Result on the web

    <a href="http://dx.doi.org/10.1088/1742-6596/444/1/012093" target="_blank" >http://dx.doi.org/10.1088/1742-6596/444/1/012093</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1088/1742-6596/444/1/012093" target="_blank" >10.1088/1742-6596/444/1/012093</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Influence of preparation and calibration method of PAGAT dosimeter on TSE MR readout results

  • Original language description

    In this study PAGAT dosimeter evaluation by TSE sequence was tested. PAGAT dosimeter preparation procedure was modified to increase the dosimeter sensitivity. Because THPC reacts with gelatin, adding THPC to monomer solution prior to dissolved gelatine helps exploit THPC as an antioxidant. Turbo spin echo sequence enables to evaluate gel dosimeter with 3D equidistant resolution in a reasonable scanning time. Glass walls of the phantom cause problems both by computing inaccuracies and MR imaging artefacts. The inner dosimeter volume is not affected by these inaccuracies and should be used for radiotherapy plan verification.

  • Czech name

  • Czech description

Classification

  • Type

    D - Article in proceedings

  • CEP classification

    BG - Nuclear, atomic and molecular physics, accelerators

  • OECD FORD branch

Result continuities

  • Project

    <a href="/en/project/FR-TI3%2F477" target="_blank" >FR-TI3/477: *Methods of optimalisation of dose distribution calculation in the patient body during spiral tomotherapy treatment using megavoltage gamma source</a><br>

  • Continuities

    Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2013

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    Journal of Physics: Conference Series - Volume 444

  • ISBN

  • ISSN

    1742-6588

  • e-ISSN

  • Number of pages

    4

  • Pages from-to

  • Publisher name

    IOP Publishing Ltd

  • Place of publication

    Bristol

  • Event location

    Sydney

  • Event date

    Nov 4, 2012

  • Type of event by nationality

    WRD - Celosvětová akce

  • UT code for WoS article

    000322968600093