All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

EURADOS intercomparison exercise on MC modelling for the in-vivo monitoring of AM-241 in skull phantoms (Part II and III).

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21340%2F15%3A00238824" target="_blank" >RIV/68407700:21340/15:00238824 - isvavai.cz</a>

  • Alternative codes found

    RIV/86652052:_____/15:#0000369

  • Result on the web

    <a href="http://dx.doi.org/10.1016/j.radphyschem.2015.04.009" target="_blank" >http://dx.doi.org/10.1016/j.radphyschem.2015.04.009</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.radphyschem.2015.04.009" target="_blank" >10.1016/j.radphyschem.2015.04.009</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    EURADOS intercomparison exercise on MC modelling for the in-vivo monitoring of AM-241 in skull phantoms (Part II and III).

  • Original language description

    An intercomparison on in-vivo monitoring for determination of Am-241 in three skull phantoms was launched by EURADOS in 2011. The project focused on measurement and estimation of the activity of Am-241 in the human skull. Three human skull phantoms of different complexity were used. A Monte Carlo (MC) intercomparison exercise with the voxel representations of the physical phantom was launched additionally in September of 2012. The main goals of the action were (1) to investigate the different methodologies for developing MC calibrations that might arise from a complex radiological assessment and (2) to compare individual approaches of the participating laboratories in order to determine international guidance for best practice. The MC exercise consisted of three tasks with increasing difficulty, in order to test the extent of skills needed by the participating laboratory. The first task was to simulate a given detector and a well-defined semi-skull phantom. The second and third tasks presented in this paper-introduced more complex simulations with individual geometry and real detector modelling. The paper provides an overview of the participant’s results, analyses of the observed issues concerning tasks two and three, and a general evaluation of the whole project.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    DL - Nuclear waste, radioactive pollution and control

  • OECD FORD branch

Result continuities

  • Project

    <a href="/en/project/VG20122014093" target="_blank" >VG20122014093: Instruments for monitoring of internal contamination in thyroide, especially of children, and transuranium radionuclide following nuclear plant accident</a><br>

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2015

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Radiation Physics and Chemistry

  • ISSN

    0969-806X

  • e-ISSN

  • Volume of the periodical

    113

  • Issue of the periodical within the volume

    AUG

  • Country of publishing house

    GB - UNITED KINGDOM

  • Number of pages

    13

  • Pages from-to

    59-71

  • UT code for WoS article

    000356196600011

  • EID of the result in the Scopus database

    2-s2.0-84929340515