Intracavity interferometry using synchronously pumped OPO
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21340%2F16%3A00307736" target="_blank" >RIV/68407700:21340/16:00307736 - isvavai.cz</a>
Result on the web
<a href="http://dx.doi.org/10.1117/12.2263640" target="_blank" >http://dx.doi.org/10.1117/12.2263640</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1117/12.2263640" target="_blank" >10.1117/12.2263640</a>
Alternative languages
Result language
angličtina
Original language name
Intracavity interferometry using synchronously pumped OPO
Original language description
The concept of system for intracavity interferometry based on the beat note detection in subharmonic synchronously intracavity pumped optical parametrical oscillator (OPO) is presented. The system consisted of SESAM-modelocked, picosecond, diode pumped Nd:YVO4 laser, operating at wavelength 1.06 μm and tunable linear intracavity pumped OPO based on MgO:PPLN crystal, widely tunable in 1.5 μm able to deliver two independent trains of picosecond pulses. The optical length of the OPO cavity was set to be exactly twice the pumping cavity length. In this configuration the OPO produces signal pulses with the same repetition frequency as the pump laser but the signal consists of two completely independent pulse trains. For purpose of pump probe measurements the setup signal with half repetition rate and scalable amplitude was derived from the OPO signal using RF signal divider, electropotical modulator and fiber amplifier. The impact of one pump beam on the sample is detected by one probing OPO train, the other OPO train is used as a reference. The beat note measured using the intracavity interferometer is proportional to phase modulation caused by the pump beam. The bandwidth of observed beat-note was less than 1 Hz (FWHM), it corresponds to a phase shift measurement error of less than 1.5 x 10-7 rad without any active stabilization. Such compact low-cost system could be used for ultra-sensitive phase-difference measurements (e.g. nonlinear refractive index measurement) for wide range of material especially in spectral range important for telecom applications
Czech name
—
Czech description
—
Classification
Type
D - Article in proceedings
CEP classification
BH - Optics, masers and lasers
OECD FORD branch
—
Result continuities
Project
<a href="/en/project/GA13-08888S" target="_blank" >GA13-08888S: Diode pumped picosecond solid state lasers</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2016
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Article name in the collection
Proceedings of SPIE Vol. 10142
ISBN
978-1-5106-0734-7
ISSN
0277-786X
e-ISSN
—
Number of pages
6
Pages from-to
—
Publisher name
The International Society for Optical Engineering (SPIE)
Place of publication
Bellingham WA
Event location
Jasná
Event date
Sep 5, 2016
Type of event by nationality
WRD - Celosvětová akce
UT code for WoS article
000393152700077