Determination of 129I by accelerator mass spectrometry in forensic analysis
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21340%2F22%3A00361995" target="_blank" >RIV/68407700:21340/22:00361995 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Determination of 129I by accelerator mass spectrometry in forensic analysis
Original language description
The nuclear forensic analysis deals with tracing the origin of nuclear materials found outside the regulatory control. Each material contains a different amount and type of radionuclides that are characteristic of each type of material. This unique composition and characteristic parameters are used to identify unknown samples. They are referred to as “fingerprints” due to their uniqueness. Nowadays, 129I is one of the most observed isotopes of iodine in the environment. The main part of 129I in the environment comes from nuclear power plants, leakage from spent nuclear fuel reprocessing facilities, from nuclear weapon tests, from nuclear accidents. It can be used for age dating, as an oceanic tracer, for water mass exchange monitoring, for research of the geochemical cycle of stable iodine. Iodine exists in nature mainly in trace amounts, so it is necessary to separate and pre-concentrate it from the samples before measuring. The separation of iodine itself is a difficult task, as it is a volatile form of iodine. Three methods are the most commonly used for solid sample preparation – alkaline leaching, acid digestion, and combustion. All methods are time-consuming and require special instrumentation or chemicals. For this purpose, there is a goal to find a new, simple, and fast technique for iodine sample preparation from solid matrices. There are many methods available for iodine determination. The most used and most accurate ones are low energy gamma-ray spectrometry, liquid scintillation counting, inductively coupled plasma mass spectrometry, and accelerator mass spectrometry. AMS is the most used method for the determination of trace amounts of iodine in the samples. It can detect an isotopic ratio of 129I/127I in order of magnitude 10-15. As a part of the RAMSES project, new laboratory with MILEA-type AMS was built in Řež, on which the samples will be measured.
Czech name
—
Czech description
—
Classification
Type
O - Miscellaneous
CEP classification
—
OECD FORD branch
10402 - Inorganic and nuclear chemistry
Result continuities
Project
<a href="/en/project/EF16_019%2F0000728" target="_blank" >EF16_019/0000728: Ultra-trace isotope research in social and environmental studies using accelerator mass spectrometry</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Others
Publication year
2022
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů