Effect of Spatial and Temporal Resolution on the Accuracy of Motion Tracking Using 2D and 3D Cine Cardiac Magnetic Resonance Imaging Data
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21340%2F23%3A00366717" target="_blank" >RIV/68407700:21340/23:00366717 - isvavai.cz</a>
Result on the web
<a href="https://doi.org/10.1007/978-3-031-35302-4_24" target="_blank" >https://doi.org/10.1007/978-3-031-35302-4_24</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/978-3-031-35302-4_24" target="_blank" >10.1007/978-3-031-35302-4_24</a>
Alternative languages
Result language
angličtina
Original language name
Effect of Spatial and Temporal Resolution on the Accuracy of Motion Tracking Using 2D and 3D Cine Cardiac Magnetic Resonance Imaging Data
Original language description
In this paper, we investigate the effect of spatial and tempo- ral resolution of cardiac MRI cine images on the extracted left ventricle motion. A previously developed and validated finite-element-based im- age registration method was used for the motion extraction. The study is performed on three subjects, for which the standard 2D cine stack (SA) in short axis orientation and 3D cine MRI series were acquired. The set of acquired image series was augmented by artificially constructed SA-like cine series created from the 3D cine images. Image series with several combinations of spatial and temporal resolution were evaluated for each subject. The study showed a strong correlation between the slice thickness and the accuracy of extracted displacement in the longitudi- nal direction. The effect of a lower temporal resolution was shown to be less significant. This could prove useful to update current guidelines for cardiac MRI acquisitions.
Czech name
—
Czech description
—
Classification
Type
D - Article in proceedings
CEP classification
—
OECD FORD branch
10201 - Computer sciences, information science, bioinformathics (hardware development to be 2.2, social aspect to be 5.8)
Result continuities
Project
<a href="/en/project/NV19-08-00071" target="_blank" >NV19-08-00071: Analysis of flow character and prediction of evolution in endovascular treated arteries by magnetic resonance imaging coupled with mathematical modeling</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2023
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Article name in the collection
Functional Imaging and Modeling of the Heart
ISBN
978-3-031-35301-7
ISSN
0302-9743
e-ISSN
1611-3349
Number of pages
10
Pages from-to
235-244
Publisher name
Springer, Cham
Place of publication
—
Event location
Lyon
Event date
Jun 19, 2023
Type of event by nationality
WRD - Celosvětová akce
UT code for WoS article
001515772300024