Case study: Dosimetric comparison of VMAT, IMRT and 3DCRT techniques for left-sided breast cancer treated in deep inspiration breath-hold

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21340%2F23%3A00369091" target="_blank" >RIV/68407700:21340/23:00369091 - isvavai.cz</a>

  • Result on the web

    <a href="https://doi.org/10.14311/AP.2023.63.0123" target="_blank" >https://doi.org/10.14311/AP.2023.63.0123</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.14311/AP.2023.63.0123" target="_blank" >10.14311/AP.2023.63.0123</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Case study: Dosimetric comparison of VMAT, IMRT and 3DCRT techniques for left-sided breast cancer treated in deep inspiration breath-hold

  • Original language description

    The aim of this case study was to compare 3D conformal radiotherapy (3DCRT) plans for patients treated for left-sided breast cancer (whole breast without positive lymph nodes in deep inspiration breath-hold (DIBH)) to volumetric modulated arc therapy (VMAT) and intensity modulated radiation therapy (IMRT) plans. The original clinical plans used tangential field-in-field 3DCRT technique with a combination of 6 MV and 18 MV photon beams. VMAT and IMRT plans were based on several previously published techniques and used 6 MV beams. Two patients were included in this case study and 4 plans were created and compared for each one. All plans were compared in terms of tumour coverage, gradient measure and conformity index, doses to organs at risk (OARs), the volume of body receiving 5 Gy and also the number of Monitor Units (MUs). While better tumour coverage and conformity was achieved with IMRT and VMAT plans, OARs were better spared with the 3DCRT technique, which also resulted in the lowest dose bath and number of MUs.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>SC</sub> - Article in a specialist periodical, which is included in the SCOPUS database

  • CEP classification

  • OECD FORD branch

    30204 - Oncology

Result continuities

  • Project

    <a href="/en/project/EF16_019%2F0000778" target="_blank" >EF16_019/0000778: Center for advanced applied science</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2023

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Acta Polytechnica

  • ISSN

    1210-2709

  • e-ISSN

    1805-2363

  • Volume of the periodical

    63

  • Issue of the periodical within the volume

    2

  • Country of publishing house

    CZ - CZECH REPUBLIC

  • Number of pages

    9

  • Pages from-to

    123-131

  • UT code for WoS article

    001032499800005

  • EID of the result in the Scopus database

    2-s2.0-85163139201