Delayed neutron library analysis using dynamic control rod calibration method based on results from the VR-1 reactor experiment and Serpent transient calculation

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21340%2F24%3A00372360" target="_blank" >RIV/68407700:21340/24:00372360 - isvavai.cz</a>

  • Result on the web

    <a href="https://doi.org/10.1016/j.anucene.2024.110685" target="_blank" >https://doi.org/10.1016/j.anucene.2024.110685</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.anucene.2024.110685" target="_blank" >10.1016/j.anucene.2024.110685</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Delayed neutron library analysis using dynamic control rod calibration method based on results from the VR-1 reactor experiment and Serpent transient calculation

  • Original language description

    This study is focused on a comparison of experimental neutron flux data from the VR-1 reactor with results from Serpent calculation. Serpent data were calculated by the dynamic part of the code and the steady-state criticality calculation. The Serpent calculation was performed with the JEFF 3.3 and ENDF/B-VIII.0 nuclear data library. This paper expands previous work and focuses on the integral control rod worth. Comparison of the ENDF/B-VIII.0 and JEFF 3.3 nuclear data libraries with experimental data is especially valuable. The comparison shows better performance of JEFF 3.3 nuclear data instead of ENDF/B-VIII.0 for the transient calculation of the cases presented in this article. In addition, the comparison of static and dynamic reactivity provided an interesting difference, especially for small rod insertion. Moreover, the study confirms that the Serpent dynamic external source simulation mode provides an accurate description of reactor behavior, and that the shape of the integral control rod worth is close to one experimentally measured.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    10304 - Nuclear physics

Result continuities

  • Project

    <a href="/en/project/LM2023073" target="_blank" >LM2023073: The VR-1 Nuclear Experimental Hub</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2024

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Annals of Nuclear Energy

  • ISSN

    0306-4549

  • e-ISSN

    1873-2100

  • Volume of the periodical

    207

  • Issue of the periodical within the volume

    November

  • Country of publishing house

    GB - UNITED KINGDOM

  • Number of pages

    7

  • Pages from-to

  • UT code for WoS article

    001255073100001

  • EID of the result in the Scopus database