Patterns of practice of image guided particle therapy for brain tumours: A site specific multi-institutional survey of the European particle therapy network
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21340%2F25%3A00388690" target="_blank" >RIV/68407700:21340/25:00388690 - isvavai.cz</a>
Result on the web
<a href="https://doi.org/10.1016/j.ejmp.2025.105211" target="_blank" >https://doi.org/10.1016/j.ejmp.2025.105211</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.ejmp.2025.105211" target="_blank" >10.1016/j.ejmp.2025.105211</a>
Alternative languages
Result language
angličtina
Original language name
Patterns of practice of image guided particle therapy for brain tumours: A site specific multi-institutional survey of the European particle therapy network
Original language description
Purpose: To investigate the current practice patterns in image-guided proton therapy (IGPT) for brain tumours. Methods: A multi-institutional survey was distributed to European particle therapy centres to analyse the current practice of IGPT for neuro-oncology. The survey was subsequently used for driving a DELPHI consensus analysis aiming at defining the minimum requirements and the optimal workflow. Results: Seven centres participated in the survey on proton therapy for brain tumours. All reported access to pencil beam scanning and rotating gantries; one also used passive scattering. Supine positioning with standard immobilisation tools was common, while prone and paediatric-specific methods were rare. Multimodal imaging with CT and MRI was standard; PET use was limited and SPECT absent. Rigid registration between imaging modalities was widely used, though MR imaging in treatment position was uncommon. Verification practices varied. Six centres joined the DELPHI consensus, reaching agreement on minimum requirements for immobilisation, imaging for treatment planning, image registration and pre-treatment setup. Disagreement remained on robustness criteria, imaging frequency, and dose tracking, highlighting the need for unified clinical guidelines and workflow optimisation. Conclusion: There is generally agreement across European proton centres, but variability remained in key components of treatment planning, verification and workflow optimisation, including the frequency and modality of control imaging, plan robustness criteria, and treatment position imaging protocols. These differences reflect both local resource availability and the absence of harmonised guidelines. The minimal requirements for image guidance in brain proton therapy achieved good consensus level and will be very useful for new centres.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10301 - Atomic, molecular and chemical physics (physics of atoms and molecules including collision, interaction with radiation, magnetic resonances, Mössbauer effect)
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2025
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS
ISSN
1120-1797
e-ISSN
1724-191X
Volume of the periodical
140
Issue of the periodical within the volume
prosinec
Country of publishing house
GB - UNITED KINGDOM
Number of pages
8
Pages from-to
—
UT code for WoS article
001616618500001
EID of the result in the Scopus database
2-s2.0-105021111369