Silver-Doped Layers of Implants Prepared by Pulsed Laser Deposition
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F13%3A00211540" target="_blank" >RIV/68407700:21460/13:00211540 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Silver-Doped Layers of Implants Prepared by Pulsed Laser Deposition
Original language description
Physical and mechanical properties of silver-doped layers of titanium alloy Ti6Al4V and 316L steel prepared by pulsed laser deposition were studied. Metallic silver-doped coatings could be a new way for antibacterial protection in medi- cine. Thin filmsof silver and silver-doped materials were synthesized using KrF excimer laser deposition. The material was ablated from two targets, which composed either from titanium alloy with silver segments or from steel with silver segments. The concentration of silver ranged from 1.54 at.% to 4.32 at.% for steel and from 3.04 at.% to 13.05 at.% for titanium alloy. The layers properties such as silver content, structure, and adhesion were measured. Adhesion was stu- died using scratch test
Czech name
—
Czech description
—
Classification
Type
O - Miscellaneous
CEP classification
BH - Optics, masers and lasers
OECD FORD branch
—
Result continuities
Project
—
Continuities
S - Specificky vyzkum na vysokych skolach
Others
Publication year
2013
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů