All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

The Effect of Dynamic Hypoinflation during High Frequency Oscillatory Ventilation in an in Vitro Model of the Respiratory System

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F15%3A00235154" target="_blank" >RIV/68407700:21460/15:00235154 - isvavai.cz</a>

  • Result on the web

    <a href="http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=7391479" target="_blank" >http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=7391479</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1109/EHB.2015.7391479" target="_blank" >10.1109/EHB.2015.7391479</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    The Effect of Dynamic Hypoinflation during High Frequency Oscillatory Ventilation in an in Vitro Model of the Respiratory System

  • Original language description

    Dynamic hyperinflation during high frequency oscillatory ventilation (HFOV) is defined as a situation when the mean alveolar pressure (mPalv) is higher than the mean airway pressure (mPaw). Lower inspiratory to expiratory time ratio (I:E) is recommendedto prevent dynamic hyperinflation. Some studies document a possibility of the opposite effect-dynamic hypoinflation (mPalv<mPaw). The aim of this study is to investigate whether dynamic hypoinflation may occur during HFOV when a linear or parabolic resistance simulating the airway resistance is present in the model of the respiratory system (RS) and whether the magnitude of the dynamic hypoinflation can be predicted based on the ventilatory parameters and setting of the HFOV ventilator. Models of the RSwith various linear and parabolic resistors were ventilated with SensorMedics 3100B ventilator with various preset parameters. The preset I:E of 1:2 and the presence of a parabolic resistance in the circuit increase the magnitude of the

  • Czech name

  • Czech description

Classification

  • Type

    D - Article in proceedings

  • CEP classification

    FS - Medical facilities, apparatus and equipment

  • OECD FORD branch

Result continuities

  • Project

    <a href="/en/project/VG20102015062" target="_blank" >VG20102015062: Research support of Fire Rescue Services of the Czech Republic (FRS) and other bodies of Integrated Rescue System of the CR (IRS</a><br>

  • Continuities

    S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2015

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    The 5th IEEE International Conference on E-Health and Bioengineering

  • ISBN

    978-1-4673-7545-0

  • ISSN

  • e-ISSN

  • Number of pages

    4

  • Pages from-to

  • Publisher name

    Gr. T. Popa University of Medicine and Pharmacy

  • Place of publication

    Iasi

  • Event location

    Iasi

  • Event date

    Nov 19, 2015

  • Type of event by nationality

    WRD - Celosvětová akce

  • UT code for WoS article