All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Center of Ventilation-Methods of Calculation using Electrical Impedance Tomography and the Influence of Image Segmentation

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F16%3A00304278" target="_blank" >RIV/68407700:21460/16:00304278 - isvavai.cz</a>

  • Result on the web

    <a href="http://dx.doi.org/10.1007/978-3-319-32703-7_241" target="_blank" >http://dx.doi.org/10.1007/978-3-319-32703-7_241</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1007/978-3-319-32703-7_241" target="_blank" >10.1007/978-3-319-32703-7_241</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Center of Ventilation-Methods of Calculation using Electrical Impedance Tomography and the Influence of Image Segmentation

  • Original language description

    Electrical impedance tomography (EIT) is a promising non-invasive, radiation-free imaging modality. Using EIT-derived index Center of ventilation (CoV), ventral-to-dorsal shifts in distribution of lung ventilation can be assessed. The methods of CoV calculation differ among authors and so does the segmentation of EIT images from which the CoV is calculated. The aim of this study is to compare the values of CoV obtained using different algorithms, applied in variously segmented EIT images. An animal trial (n=4) with anesthetized mechanically ventilated pigs was conducted. In one animal, acute respiratory distress syndrome (ARDS) was induced by repeated whole lung lavage. Incremental steps in positive end-expiratory pressure (PEEP), each with a value of 5 cmH(2)O (or 4 cmH(2)O in the ARDS model), were performed to reach total PEEP level of 25 cmH(2)O (or 22 cmH(2)O in the ARDS model). EIT data were acquired continuously during this PEEP trial. From each PEEP level, 30 tidal variation (TV) images were used for analysis. Functional regions of interest (ROI) were defined based on the standard deviation (SD) of pixel values, using threshold 15%-35% of maximum pixel SD. The results of this study show that there might be statistically significant differences between the values obtained using different methods for calculation of CoV. The differences occured in healthy animals as well as in the ARDS model. Both investigated algorithms are relatively insensitive to the image segmentation.

  • Czech name

  • Czech description

Classification

  • Type

    D - Article in proceedings

  • CEP classification

    FS - Medical facilities, apparatus and equipment

  • OECD FORD branch

Result continuities

  • Project

  • Continuities

    S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2016

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    XIV MEDITERRANEAN CONFERENCE ON MEDICAL AND BIOLOGICAL ENGINEERING AND COMPUTING 2016

  • ISBN

    978-3-319-32703-7

  • ISSN

    1680-0737

  • e-ISSN

  • Number of pages

    6

  • Pages from-to

    1258-1263

  • Publisher name

    Springer

  • Place of publication

    New York

  • Event location

    Paphos

  • Event date

    Mar 31, 2016

  • Type of event by nationality

    WRD - Celosvětová akce

  • UT code for WoS article

    000376283000241