All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Monte Carlo simulations of risky non-standard operations during handling radiopharmaceuticals

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F16%3A00306642" target="_blank" >RIV/68407700:21460/16:00306642 - isvavai.cz</a>

  • Result on the web

  • DOI - Digital Object Identifier

Alternative languages

  • Result language

    angličtina

  • Original language name

    Monte Carlo simulations of risky non-standard operations during handling radiopharmaceuticals

  • Original language description

    The aim of this work is to introduce an identifying the non-standard risky operations and determining the values of personal dose equivalent Hp(0,07) at the point of maximum exposure on hands. Materials and methods: The non-standard risky operations have been identified by interviews with staff, by control of video records or by reading of personal ring dosimeter. The MCNPX code and three voxel phantoms simulating various hand operations were used for searching of locality on hand with point of maximum exposure. Validation of MCNPX simulations of the voxel phantoms were performed in comparison with experiments with the physical phantoms. The thermoluminescent dosimeters of type MCP-Ns for measurements of the dose equivalent Hp (0.07) were used. Results: The proposed method for identification of the non-standard risky operations during the administration to patient the liquid 131I in cup and 18F-FDG in syringe has been used. The MC simulations of voxel phantom of hand holding unshielded syringe with 18F-FDG have shown significant (more than 4- fold ) increase of the dose Hp (0.07) on the hands at the points of maximum exposure that were in different localities than these that were monitored by TLD. By simulations of the voxel phantom of the hand has been shown to penetrating of 18F positrons through walls of unshielded syringe with 18F-FDG and the contribution of positron dose to hand irradiation was determined. Similarly, the contribution to the local electron irradiation of the skin in the palm handling unshielded cup with 131I was calculated.

  • Czech name

  • Czech description

Classification

  • Type

    O - Miscellaneous

  • CEP classification

    AQ - Safety and health protection, safety in operating machinery

  • OECD FORD branch

Result continuities

  • Project

  • Continuities

    S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2016

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů