All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Determining ablation depth and ablation threshold for tissue using CT imaging

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F18%3A00326346" target="_blank" >RIV/68407700:21460/18:00326346 - isvavai.cz</a>

  • Result on the web

  • DOI - Digital Object Identifier

Alternative languages

  • Result language

    angličtina

  • Original language name

    Determining ablation depth and ablation threshold for tissue using CT imaging

  • Original language description

    Photoablation occurs in laser-irradiated tissue when the laser parameters are adjusted appropriately. This effectively removes the target tissue directly by breaking the molecular bonds and expunging the decomposed fragments. Excimer lasers in pulse mode emit photons carrying enough energy to break the bonds. To analyze the profile of ablation craters and their depth, a new method using CT imaging was developed and verified. Values of depth determined through this method were compared with values obtained by other methods. The aim of our experiments was to determine the ablation depth – the thickness of the layer removed with a single laser pulse in photoablation for different types of tissue. It was determined by dividing the ablation crater depth values obtained through CT imaging by the number of applied laser pulses. Experimentally obtained values of all measured variables are in accordance with values obtained in previous experiments, and with values available in current publications.

  • Czech name

  • Czech description

Classification

  • Type

    O - Miscellaneous

  • CEP classification

  • OECD FORD branch

    20602 - Medical laboratory technology (including laboratory samples analysis; diagnostic technologies) (Biomaterials to be 2.9 [physical characteristics of living material as related to medical implants, devices, sensors])

Result continuities

  • Project

  • Continuities

    S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2018

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů