Methods of motion assessment of smart orthosis of upper limb for rehabilitation at the clinic and at home
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F19%3A00321939" target="_blank" >RIV/68407700:21460/19:00321939 - isvavai.cz</a>
Alternative codes found
RIV/00216208:11130/18:10376513 RIV/00064203:_____/18:10376513
Result on the web
<a href="https://link.springer.com/chapter/10.1007%2F978-981-10-9038-7_144" target="_blank" >https://link.springer.com/chapter/10.1007%2F978-981-10-9038-7_144</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/978-981-10-9038-7_144" target="_blank" >10.1007/978-981-10-9038-7_144</a>
Alternative languages
Result language
angličtina
Original language name
Methods of motion assessment of smart orthosis of upper limb for rehabilitation at the clinic and at home
Original language description
The aim of this work is to describe proposed and tested methods for evaluation of short-term and long-term movement activity of a smart orthosis for the upper limbs during a rehabilitation process carried out at a clinic or at home. To quantify the description of motion we used methods of evaluation of the time domain data. To test the functionality of the methods, we compared the movement of the dominant and non-dominant limbs, assuming cyclical and acyclic movement, to obtain the expected values for a healthy population. In accordance with the goal, a group of cyclic and non-cyclic movements common to the home environment were proposed. The movements were divided according to the activities performed during sitting, standing and walking. It was: pen writing, typing on the keyboard/using the mouse, eating with a spoon and eating a croissant combing, lifting weights, reading a book, etc. Twenty healthy subjects participated in the study. Four gyro-accelerometers (Xsens Technologies B.V.) attached to the forearms and upper arms of both upper limbs were used to record the upper limb movements. The results show that the calculated values of dominant and non-dominant limb parameters differ significantly in acyclic movements. The smart orthosis which uses the proposed methods can be used to evaluate the physical activity, quantify the evaluation of the rehabilitation process, and thus, it finds use in clinical practice.
Czech name
—
Czech description
—
Classification
Type
D - Article in proceedings
CEP classification
—
OECD FORD branch
20601 - Medical engineering
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2019
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Article name in the collection
World Congress on Medical Physics and Biomedical Engineering 2018 (Vol. 2)
ISBN
978-981-10-9037-0
ISSN
1680-0737
e-ISSN
—
Number of pages
5
Pages from-to
779-783
Publisher name
Springer Nature Singapore Pte Ltd.
Place of publication
—
Event location
Prague
Event date
Jun 3, 2018
Type of event by nationality
WRD - Celosvětová akce
UT code for WoS article
000449742700144