All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Changes of Body Composition and Bioimpedance During Pregnancy-Pilot Study in Czech Republic

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F19%3A00339021" target="_blank" >RIV/68407700:21460/19:00339021 - isvavai.cz</a>

  • Alternative codes found

    RIV/68407700:21730/19:00339021

  • Result on the web

    <a href="https://doi.org/10.1007/978-981-10-9038-7_169" target="_blank" >https://doi.org/10.1007/978-981-10-9038-7_169</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1007/978-981-10-9038-7_169" target="_blank" >10.1007/978-981-10-9038-7_169</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Changes of Body Composition and Bioimpedance During Pregnancy-Pilot Study in Czech Republic

  • Original language description

    Monitoring of specific physiological values during gestation process is a very important process. Body composition values and directly measured bioimpedance values however are currently not included into this monitoring although these values can help to track healthy process of gestation. In this work we are presenting new possible measurements of progress of body composition and electrical values during whole gestation process in Czech population. Bioelectrical resistance, reactance and body composition values were measured by BIA device Tanita MC 180 MA on 5, 50, 250 and 500 kHz. BIA measurements from 10 women were evaluated during second and third trimester of pregnancy. We discovered changes in directly measured electrical values and calculated values during a gestation period. Statistically significant increase was discovered in calculated body composition values: Weight (kg) (P = 0.005), Fat mass (kg) (P = 0.01), TBW (kg) (P = 0.005). Statistical significant (P = 0.05) decrease on all used frequencies was discovered in resistance and reactance values. Average decrease of resistance across all frequencies was 73.17 +/- 7.62 Omega which presented 11.92 +/- 0.07%. Results suggest that body composition values and especially directly measured values that are not equation dependent can give precise description for gestation process and can be used as one of the markers of healthy gestation process in future. Hence this measuring and evaluating of directly measured electrical values and body composition values can give us more information about gestation process.

  • Czech name

  • Czech description

Classification

  • Type

    D - Article in proceedings

  • CEP classification

  • OECD FORD branch

    20601 - Medical engineering

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2019

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    World Congress on Medical Physics and Biomedical Engineering 2018 (Vol. 2)

  • ISBN

    978-981-10-9037-0

  • ISSN

    1680-0737

  • e-ISSN

  • Number of pages

    4

  • Pages from-to

    917-920

  • Publisher name

    Springer Nature Singapore Pte Ltd.

  • Place of publication

  • Event location

    Prague

  • Event date

    Jun 3, 2018

  • Type of event by nationality

    WRD - Celosvětová akce

  • UT code for WoS article

    000449742700169