Evaluation of Decentration, Tilt and Angular Orientation of Toric Intraocular Lens
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F21%3A00353500" target="_blank" >RIV/68407700:21460/21:00353500 - isvavai.cz</a>
Result on the web
<a href="https://doi.org/10.2147/OPTH.S346968" target="_blank" >https://doi.org/10.2147/OPTH.S346968</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.2147/OPTH.S346968" target="_blank" >10.2147/OPTH.S346968</a>
Alternative languages
Result language
angličtina
Original language name
Evaluation of Decentration, Tilt and Angular Orientation of Toric Intraocular Lens
Original language description
Purpose: The aim of this study was to develop software for the universal objective evaluation of factors influencing intraocular correction of astigmatism, such as decentration, tilt, axial position and angular orientation the toric intraocular lens (IOL). Patients and Methods: Software was developed using the MS Visual Studio environment. The analysis was presented using images of 67 eyes with an implanted IOLs of the SN6ATx model series. Decentration and angular position of the lens were obtained from images of the anterior segment of the eye, using a Visucam unit. Tilt was measured on tomographic images from OCT Avanti (in meridian of highest tilt and perpendicular meridian) and preoperative biometry parameters of eye (axial length, anterior chamber depth – ACD, ocular lens thickness – LT, limbus diameter and mean keratometry value) including postoperative anterior chamber depth (pACD) were measured using Lenstar LS900. Results: Applying the software methodology to the evaluation of individual toric IOL parameters, the following results were obtained: mean decentration 0.25 ± 0.17 mm which was observed in 61.19% of eyes, mean misalignment to the planned axis equal to 3.8 ± 3.6 degrees, mean highest inclination equal to 3.7 ± 1.2 degrees and mean difference of pACD and ACD was equal to 1.46 ± 0.31 mm. There was only a weak nonsignificant correlation between preoperative ACD versus decentration and tilt of IOL or a weak significant correlation between preoperative LT and both decentration and misalignment of IOL. Conclusion: The use of the presented methodology for determining the positional parameters of the toric IOL provided comparable results with the results of recent studies. Software design can be considered as a suitable alternative to previously published techniques, with the significant advantage of the possibility of using universal input images, their graphical editing and especially the possibility of comprehensive analysis of all parameters.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30207 - Ophthalmology
Result continuities
Project
—
Continuities
S - Specificky vyzkum na vysokych skolach
Others
Publication year
2021
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Clinical Ophthalmology
ISSN
1177-5483
e-ISSN
1177-5483
Volume of the periodical
—
Issue of the periodical within the volume
15
Country of publishing house
NZ - NEW ZEALAND
Number of pages
7
Pages from-to
4755-4761
UT code for WoS article
000736943800006
EID of the result in the Scopus database
—